5B36
Input-to-Power, Continuous
Output-to-Power, Continuous2
Transient
1500 V rms, maximum
250 V rms, maximum
ANSI/IEEE C37.90.1-1989
Common Mode Rejection (CMR)
170 dB
1 kΩ Source Imbalance, 50/60 Hz
Normal Mode Rejection (NMR)
116 dB @ 60 Hz; 108 dB @ 50 Hz
Sensor Excitation Current
0.25 mA
100 Ω, 500 Ω, 1 kΩ Sensors
10 kΩ Sensor
0.1 mA
Lead Resistance Effect
±0.005 Ω /Ω
100 Ω, 500 Ω, 1 kΩ Sensors
10 kΩ Sensor
±0.01 Ω /Ω
Input Protection
240 V rms, maximum
ANSI/IEEE C37.90.1-1989
25 Ω
Continuous
Transient
Output Resistance
Voltage Output Protection
Output Current Limit
Output Selection Time
Continuous Short to Ground
±9 mA
6 µs to ±1 mV of Vout @ Cload = 0 to 2,000 pF
Output Enable Control2
+0.8 V
Max Logic "0"
Min Logic "1"
+2.4 V
Max Logic "1"
+100 V
Input Current "0", "1"
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity, RTI
Mechanical Dimensions
0.5 µA
+5 V dc ±5%
15 mA
±2 µV/% of Vs
2.275" x 2.375" x 0.595"
(57.8 mm x 59.1 mm x 15.1 mm)
Environmental
Temperature Range
Rated Performance
Operating
-40°C to +85°C
-40°C to +85°C
Storage
-40°C to +85°C
Relative Humidity
RFI Susceptibility
0 to 93% @ +40°C non-condensing
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
* ±0.025 Ω For Cu RTD's; ±0.1 Ω For Ni RTD's.
1Includes the combined effects of repeatability, hysteresis, and nonlinearity error. Loads heavier than 50 kΩ will degrade nonlinearity and gain temperature coefficient.
2The user's board layout must separate Power Common from Output Common. When the output switch is not used, connect the Enable Input to the Output Common. Output
Common is connected to power common when the 5B36 is installed on a 5B Series backplane.
Specifications subject to change without notice.
Rev. 0 | Page 4 of 8