欢迎访问ic37.com |
会员登录 免费注册
发布采购

5B34-12-FC 参数 Datasheet PDF下载

5B34-12-FC图片预览
型号: 5B34-12-FC
PDF下载: 下载PDF文件 查看货源
内容描述: [Analog Circuit]
分类和应用:
文件页数/大小: 8 页 / 693 K
品牌: ADI [ ADI ]
 浏览型号5B34-12-FC的Datasheet PDF文件第1页浏览型号5B34-12-FC的Datasheet PDF文件第2页浏览型号5B34-12-FC的Datasheet PDF文件第3页浏览型号5B34-12-FC的Datasheet PDF文件第5页浏览型号5B34-12-FC的Datasheet PDF文件第6页浏览型号5B34-12-FC的Datasheet PDF文件第7页浏览型号5B34-12-FC的Datasheet PDF文件第8页  
5B34  
Output Rise Time, 10% to 90% Span  
200 ms  
Common-Mode Voltage (CMV)  
1500 V rms, maximum  
±3 V, maximum  
Input-to-Output, Continuous  
Output-to-Power, Continuous4  
Transient  
ANSI/IEEE C37.90.1-1989  
Common Mode Rejection (CMR)  
160 dB  
1 kSource Imbalance, 50/60 Hz  
Normal Mode Rejection 50/60 Hz  
60 dB  
Sensor Excitation Current  
0.25 mA  
100Pt, 120Ni  
10Cu  
1.0 mA  
Lead Resistance Effect  
100Pt, 120Ni  
10Cu  
±0.02°C/Ω  
±0.2°C/Ω  
Input Protection  
Continuous  
240 V rms, maximum  
Transient  
ANSI/IEEE C37.90.1-1989  
Output Resistance  
Voltage Output Protection  
Output Selection Time  
50Ω  
Continuous Short to Ground  
6 µs @ Cload = 0 to 2,000 pF  
Output Enable Control  
Max Logic "0"  
+1 V  
Min Logic "1"  
+2.5 V  
Max Logic "1"  
+36 V  
Input Current "0"  
Power Supply Voltage  
Power Supply Current  
0.4 mA  
+5 V ±5%  
30 mA  
Power Supply Sensitivity, RTI  
±0.05°C/V  
100Pt, 120Ni  
10Cu  
±0.5°C/V  
Mechanical Dimensions  
2.275" x 2.375" x 0.595" (57.8 mm x 59.1 mm x 15.1 mm)  
Environmental  
Rated Performance  
Operating  
-25°C to +85°C  
-40°C to +85°C  
Storage  
-40°C to +85°C  
Relative Humidity  
RFI Susceptibility  
0 to 93% @ +40°C non-condensing  
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft  
* ±0.025For Cu RTD's; ±0.1For Ni RTD's.  
1 Rz is the value of the RTD resistance at the lowest point of the measurement range.  
2 Includes the combined effects of repeatability, hysteresis,  
and conformity error. Loads heavier than 50 kwill degrade conformity and gain temperature coefficient.  
3 For Pt RTD's only; other types may vary.  
4 The output common must be kept within ±3 V of power common.  
Specifications subject to change without notice.  
Rev. 0 | Page 4 of 8