5B30 / 5B31  
GENERAL DESCRIPTION  
mode (nosie on signal return) rejection at 50/60 Hz, enabling  
accurate measurement of small signals in high electrical noise.  
The 5B30 and 5B31 are single-channel signal conditioning  
modules that amplify, protect, filter and isolate analog input  
voltages.  
Signal isolation by transformer coupling uses a proprietary  
modulation technique for linear, stable and reliable  
The 5B30 and 5B31 protect the computer side from damage due  
to field-side over voltage faults. All models withstand 240V rms  
at their input terminals without damage thereby shielding  
computer side circuitry from field-side over voltage conditions.  
In addition, 5B30 and 5B31 Series modules are mix-and-match  
and hot swappable, so can be inserted or removed from any  
socket in the same backplane without disrupting system power.  
performance. The differential input circuit on the field side is  
fully floating, eliminating the need for any input grounding. A  
demodulator on the computer side of the signal transformer  
recovers the original signal, which is then filtered and buffered  
to provide a low-noise, low-impedance output signal. The  
output common must be kept within +3 V of power common.  
A series output switch eliminates the need for external  
multiplexing in many applications. The switch is turned on by  
an active-low enable input. If the switch is to be on at all times,  
the enable-input should be grounded to power common as it is  
on the 5B01 and 5B08 backplanes.  
A chopper-stabilized input amplifier provides low drift and  
stable gain. At the amplifier input, a stable, laser-trimmed zero-  
scale input voltage is subtracted from the input signal to set the  
zero scale value. For user convenience, the zero can be  
optionally factory-set to meet custom needs. This allows  
suppression of a zero-scale input value many times larger that  
the total span for precise expanded-scale measurements.  
Internal multi-pole low-pass filtering with a four-Hz cutoff (-  
3dB) enhances normal-mode (noise on signal) and common-  
.
Figure2  