 浏览型号5962R8954203VGA的Datasheet PDF文件第2页浏览型号5962R8954203VGA的Datasheet PDF文件第3页浏览型号5962R8954203VGA的Datasheet PDF文件第4页浏览型号5962R8954203VGA的Datasheet PDF文件第5页浏览型号5962R8954203VGA的Datasheet PDF文件第7页浏览型号5962R8954203VGA的Datasheet PDF文件第8页浏览型号5962R8954203VGA的Datasheet PDF文件第9页浏览型号5962R8954203VGA的Datasheet PDF文件第10页  
TABLE I. Electrical performance characteristics – Continued.  
Conditions 1/ 2/ 3/  
-55°C T +125°C  
unless otherwise specified  
Test  
Symbol  
Group A  
subgroups  
Device  
type  
Limits  
Max  
Unit  
A
Min  
86  
Supply current  
1
All  
4.0  
mA  
I
V
= 0 V  
CC  
O
2,3  
1
11.0  
4.0  
M,D,P,L,R  
= ±10 V to ±18 V  
03  
All  
Power supply rejection 4/  
PSRR  
SR  
1
dB  
V
A
S
ratio  
2,3  
7
85  
10  
7
Slew rate 4/  
01, 03  
02  
V/µs  
= +1V,  
VCL  
8a  
7
R 2 kΩ,  
L
7.5  
4.5  
3.5  
C = 100 pF  
L
8a  
7
Gain bandwidth product 4/  
GBW  
01, 03  
02  
MHz  
f
f
= 100 kHz, T = +25°C  
A
O
O
2.5  
= 87.5 kHz, T = +25°C  
A
Power dissipation 4/  
Settling time  
1
All  
120  
4
mW  
P
V = 0 V, T = +25°C  
O A  
D
6/  
9, 10  
All  
µs  
t
S
1/ Devices supplied to this drawing will meet all levels M, D, P, L, R of irradiation. However, this device is only tested at  
the ‘R’ level. Pre and Post irradiation values are identical unless otherwise specified in table I. When performing post  
irradiation electrical measurements for any RHA level, T = +25°C, and ±V = ±15 V.  
A
S
2/ These parts may be dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects.  
Radiation end point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883,  
method 1019, condition A.  
3/  
V = ±15 V, R = 50 Ω, unless otherwise specified.  
S S  
4/ This parameter is not tested post-irradiation.  
5/ Subgroup 3 is guaranteed if not tested.  
6/ Subgroup 10 is guaranteed if not tested.  
SIZE  
STANDARD  
5962-89542  
A
MICROCIRCUIT DRAWING  
DLA LAND AND MARITIME  
REVISION LEVEL  
E
SHEET  
COLUMBUS, OHIO 43218-3990  
6
DSCC FORM 2234  
APR 97