TABLE I. Electrical performance characteristics – continued.
Conditions
-55°C ≤ TA ≤ +125°C
VCC = +15 V, VLOG = +5 V,
Group A
subgroups
Device
type
Limits
Unit
Test
Symbol
VEE = -15 V 1/
unless otherwise specified
TA = +25°C
Min
Max
0.25
1
1
1
01, 02
01, 02
03, 04,
05, 06,
07, 08
01
% of
F.S.
∆AE
Gain error
M, D, P, L, R
With 50Ω resistor from
REF OUT to REF IN
0.35
0.30
12
1, 2, 3 3/
2, 3
0.125
12.5
Using internal reference
01
-12.5
-25.0
-1.0
∆AE
∆T
ppm/°C
Gain error drift
2/
03,
05, 07
02
1, 2, 3 3/
2, 3
25.0
1.0
04,
06, 08
All
+PSS1
+PSS2
+PSS3
-PSS1
-PSS2
ZIN
+13.5 V < VCC < +16.5 V
TA = +25°C
1
LSB
Power supply sensitivity
(Maximum change in
full scale calibration)
2/
+11.4 V < VCC < +12.6 V
TA = +25°C
+4.5 V < VLOG < +5.5 V
TA = +25°C
1
1
All
All
-0.5
-1.0
0.5
1.0
-16.5 V < VEE < -13.5 V
TA = +25°C
-12.6 V < VEE < -11.4 V
TA = +25°C
4
4
All
3
6
7
10 V span, TA = +25°C
20 V span, TA = +25°C
kΩ
Input Impedance
2/
01, 02,
03, 04
05, 06,
07, 08
01, 02
01, 02
03, 04
07, 08
05, 06
01
14
15
25
VREF
1
1
1
9.98
9.95
9.90
10.02
10.05
10.10
V
TA = +25°C
4/
Internal reference voltage
M, D, P, L, R
9.97
9.99
10.03
10.01
1.5
12
1
IO
Available for external loads
01, 02,
03, 04
05, 06,
07, 08
mA
Output current
2/, 5/
TA = +25°C
2.0
See footnotes at end of table.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-85127
A
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
REVISION LEVEL
H
SHEET
7
DSCC FORM 2234
APR 97