TABLE I. Electrical performance characteristics – continued.
Conditions 1/ 2/ 3/
-55°C ≤ T ≤ +125°C
unless otherwise specified
Test
Symbol
Group A
subgroups
Device
type
Limits
Unit
A
Min
35
Max
Power supply section – continued.
Maximum positive supply
1
01, 02
55
mA
I
V
= 5.25 V,
PSmax
PS
current
ENABLE = 2 V
2
3
42
25
35
35
62
45
55
55
M,D,P,L,R
M,D,P,L
1
1
01
02
Standby positive supply
current
V
= 3 V; V = 5 V;
PS
PS
1,2,3
01, 02
20
µA
I
Standby
ENABLE = 0.5 V
M,D,P,L,R
M,D,P,L
1
1
01
02
20
20
1/ Unless otherwise specified, f = local oscillator (LO) frequency = 1.9 GHz, LO input level = -10 dBm;
LO
BB frequency = 1MHz; BB inputs are dc-biased to 1.2 V; BB input level = 1 Vp-p each pin for 2 Vp-p differential drive;
VPS1 = VPS2 = V , LO source and RF output load impedances are 50 Ω, dBm units are referenced to 50 Ω unless
PS
otherwise noted.
2/ Device type 01 supplied to this drawing has been characterized through all levels M, D, P, L, R of irradiation. Device type
02 supplied to this drawing has been characterized through all levels M, D, P, L of irradiation. However,
device type 01 is only tested at the “R” level and device type 02 is only tested at the “L” level. Pre and Post irradiation
values are identical unless otherwise specified in Table I. When performing post irradiation electrical measurements for any
RHA level, T = +25°C.
A
3/ For device type 01, this part may be dose rate sensitive in a space environment and may demonstrate enhanced low
dose rate effects. Radiation end point limits for the noted parameters are guaranteed only for the conditions specified
in MIL-STD-883, method 1019, condition A for device type 01 and condition D for device type 02. Device type 02, has been
tested at low dose rate.
4/
f
= 2.5 GHz operation is achievable but not production tested. Contact manufacturer for more information.
LO
5/ For increased subgroup 5 output power at f = 1.9 GHz and f = 2.3 GHz, use LO input level of -6 dBm.
LO LO
6/ Not tested post irradiation.
7/ Parameter tested as part of device initial characterization and after design and process changes.
BB input level = 0.9 Vp-p each input for 1.8 Vp-p differential drive.
SIZE
STANDARD
5962-09227
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
B
SHEET
COLUMBUS, OHIO 43218-3990
21
DSCC FORM 2234
APR 97