TABLE I. Electrical performance characteristics – Continued.
Conditions 1/ 2/
-55C T +125C
unless otherwise specified
Test
Symbol
Group A
subgroups
Device
type
Limits
Max
Unit
A
Min
350
4
5, 6
4, 5, 6
1, 2, 3
1
02, 04
V/mV
A
VS
V = 10 V, 3/
O
Large-signal voltage gain
250
R = 2 k
L
All
V
RL = 2 k 3/
12
V
OP
Output voltage swing
Supply current 4/
No load
All
11
11
11
mA
I
S
M,D,P,L,R
M,D,P,L
01, 02
03, 04
01, 03
02, 04
01, 03
1
SR
7
1.4
6.5
V/s
A
= +21, R = 10 k,
L
Slew rate
VCL
T
= +25C 3/
A
CMR
1
2, 3
1
110
100
105
100
dB
V
= IVR = 11 V 3/ 5/
Common-mode rejection
CM
02, 04
01, 03
02, 04
2, 3
1
PSRR
1.8
5.6
5.6
10
V/V
V
= 4.5 V to 18 V 3/
Power supply rejection ratio
CC
2, 3
1
2, 3
1/ Device types 01 and 02 supplied to this drawing has been characterized through all levels M, D, P, L, R of irradiation.
Device types 03 and 04 supplied to this drawing has been characterized through all levels M, D, P, L of irradiation.
However, device types 01 and 02 is only tested at the “R” level and device types 03 and 04 is only tested at the “L” level.
Pre and Post irradiation values are identical unless otherwise specified in Table I. When performing post irradiation
electrical measurements for any RHA level, T = +25C. V
= 15 V, R = 50 .
S
A
CC
2/ For device types 01 and 02, these parts may be dose rate sensitive in a space environment and may demonstrate
enhanced low dose rate effects. Radiation end point limits for the noted parameters are guaranteed only for the conditions
specified in MIL-STD-883, method 1019, condition A for device types 01 and 02 and condition D for device types 03 and 04.
Device types 03 and 04, have been tested at low dose rate.
3/ This parameter is not tested post-irradiation.
4/
I limit equals the total of all amplifiers.
S
5/ IVR is defined as the V
range used for the CMR test.
CM
SIZE
STANDARD
5962-88565
A
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
REVISION LEVEL
SHEET
COLUMBUS, OHIO 43218-3990
H
6
DSCC FORM 2234
APR 97