OP470
Very low noise, quad, operational amplifier
Table I - Electrical Characteristics (continued)
Conditions
1/
Sub-
groups
Limit
Min
Limit
Max
Parameter
Symbol
VOP
Units
V
Output Voltage Swing 4/
Supply Current 2/
RL = 2Kohm
No Load
4, 5, 6,
1, 2, 3
1
±12
11
11
ISY
mA
M, D, L, R
Input Voltage Range 4/
Slew Rate 4/
IVR
SR
1, 2, 3
7
±11
1.4
V
V/μV
AVLC = +21, RL = 10kΩ
1
2, 3
1
110
100
Common Mode Rejection 4/ CMR
VCM = IVR 3/
dB
1.8
5.6
Power Supply Rejection
PSRR
VS = ±4.5V to ±18V
μV/V
Ratio 4/
2, 3
Table I Notes:
1/ VS = ±15V, RS = 50Ω, unless otherwise specified.
2/ ISY limit equals the total of all four amplifiers.
3/ IVR is defined as the VCM range used for the CMR test.
4/ Not tested Post Irradiation.
4.1
Electrical Test Requirements:
Table II
Subgroups (in accordance with
MIL-PRF-38535, Table III)
Test Requirements
Interim Electrical Parameters
Final Electrical Parameters
Group A Test Requirements
1
1, 2, 3, 4, 5, 6 1/ 2/
1, 2, 3, 4, 5, 6, 7
Group C end-point electrical parameters 1, 2, 3 2/
Group D end-point electrical parameters
Group E end-point electrical parameters
1
1
1/ PDA applies to Subgroup 1 only. Delta's excluded from PDA.
2/ See Table III for delta parameters. See table I for conditions.
4.2
Life Test and Burn-In Delta Limits:
Table III
TEST
BURN-IN
LIFETEST
DELTA
LIMIT
TITLE
ENDPOINT ENDPOINT
UNITS
VIO
IIB
±0.4
±25
±10
±0.5
±30
±15
±0.1
±5
mV
nA
nA
IIO
±5
ASD0013059 Rev. B
25-Sep-07
Page 3 of 5