OP470  
4. The test time to measure 0.1 Hz to 10 Hz noise should not ex-  
ceed 10 seconds. As shown in the noise-tester frequency-response  
curve of Figure 8, the 0.1 Hz corner is defined by only one pole.  
The test time of 10 seconds acts as an additional pole to elimi-  
nate noise contribution from the frequency band below 0.1 Hz.  
The OP470 is a monolithic device with four identical amplifiers.  
The noise voltage density of each individual amplifier will match,  
giving:  
Ê
2 ˆ  
¯
eOUT = 101 4en  
= 101 2e  
n
(
)
Ë
5. A noise-voltage-density test is recommended when measuring  
noise on a large number of units. A 10 Hz noise voltage-density  
measurement will correlate well with a 0.1 Hz to 10 Hz  
peak-to-peak noise reading, since both results are determined  
by the white noise and the location of the 1/f corner frequency.  
NOISE MEASUREMENT—CURRENT NOISE DENSITY  
The test circuit shown in Figure 10 can be used to measure  
current noise density. The formula relating the voltage output to  
current noise density is:  
6. Power should be supplied to the test circuit by well bypassed  
low noise supplies, e.g. batteries. These will minimize output  
noise introduced via the amplifier supply pins.  
Ê nOUT ˆ2  
2
- 40nV / Hz  
Á
˜
(
)
G
Ë
¯
in =  
100  
80  
60  
40  
20  
0
RS  
where:  
G = gain of 10000  
RS = 100 kW source resistance  
R3  
1.24kꢅ  
R2  
R1  
100kꢅ  
5ꢅ  
OP470  
DUT  
e
OUT TO  
OP27E  
n
SPECTRUM ANALYZER  
R5  
8.06kꢅ  
0.01  
0.1  
1
10  
100  
FREQUENCY – Hz  
R4  
200ꢅ  
GAIN = 50,000  
= 5V  
Figure 8. 0.1 Hz to 10 Hz Peak-to-Peak Voltage Noise Test  
Circuit Frequency Response  
V
S
Figure 10. Current Noise Density Test Circuit  
NOISE MEASUREMENT—NOISE VOLTAGE DENSITY  
The circuit of Figure 9 shows a quick and reliable method of  
measuring the noise voltage density of quad op amps. Each  
individual amplifier is series-connected and is in unity-gain, save  
the final amplifier which is in a noninverting gain of 101. Since  
the ac noise voltages of each amplifier are uncorrelated, they  
add in rms fashion to yield:  
Ê
2 ˆ  
¯
2
2
2
eOUT = 101 enA + enB + enC + enD  
Ë
R1  
R2  
100ꢅ  
10kꢅ  
1/4  
e
OUT  
OP470  
1/4  
OP470  
TO SPECTRUM ANALYZER  
1/4  
OP470  
1/4  
OP470  
e
V
(nV Hz) = 101(2e )  
n
OUT  
= 15V  
S
Figure 9. Noise Voltage Density Test Circuit  
REV. B  