AD10465
ABSOLUTE MAXIMUM RATINGS1
TEST LEVEL
I. 100% Production Tested.
Parameter
Min Max Units
II. 100% Production Tested at 25°C, and sample tested at
ELECTRICAL
VCC Voltage
VEE Voltage
Analog Input Voltage
Analog Input Current
Digital Input Voltage (ENCODE)
ENCODE, ENCODE Differential Voltage
Digital Output Current
specified temperatures. AC testing done on sample basis.
0
–7
7
0
V
V
V
III. Sample Tested only.
VEE VCC
–10 +10 mA
0
IV. Parameter is guaranteed by design and characterization
testing.
VCC
4
V
V
V. Parameter is a typical value only.
–10 +10 mA
VI. 100% production tested at temperature at 25°C, sample
tested at temperature extremes.
ENVIRONMENTAL2
Operating Temperature (Case)
Maximum Junction Temperature
Lead Temperature (Soldering, 10 sec)
Storage Temperature Range (Ambient)
–40 +85 °C
174 °C
300 °C
–65 +150 °C
NOTES
1Absolute maximum ratings are limiting values applied individually, and beyond
which the serviceability of the circuit may be impaired. Functional operability is
not necessarily implied. Exposure to absolute maximum rating conditions for an
extended period of time may affect device reliability.
2Typical thermal impedance for “ES” package: θJC = 2.2°C/W; θJA = 24.3°C/W.
ORDERING GUIDE
Temperature Range Package Description
Model
AD10465AZ
AD10465BZ
–25°C to +85°C (Case) 68-Lead Ceramic Leaded Chip Carrier
–40°C to +85°C (Case) 68-Lead Ceramic Leaded Chip Carrier
5962-9961601HXA –40°C to +85°C (Case) 68-Lead Ceramic Leaded Chip Carrier
AD10465/PCB
25°C
Evaluation Board with AD10465AZ
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD10465 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–
REV. 0