5962-9760101HXC 参数 Datasheet PDF下载

5962-9760101HXC图片预览
型号: 5962-9760101HXC
PDF下载: 下载PDF文件 查看货源
内容描述: 28 V / 66 W / 100 W和积分EMI滤波器的DC / DC转换器 [28 V/66 W/100 W DC/DC Converters with Integral EMI Filter]
分类和应用: 转换器电源电路局域网
文件页数/大小: 18 页 / 244 K
品牌: ADI [ ADI ]
 浏览型号5962-9760101HXC的Datasheet PDF文件第1页浏览型号5962-9760101HXC的Datasheet PDF文件第2页浏览型号5962-9760101HXC的Datasheet PDF文件第4页浏览型号5962-9760101HXC的Datasheet PDF文件第5页浏览型号5962-9760101HXC的Datasheet PDF文件第6页浏览型号5962-9760101HXC的Datasheet PDF文件第7页浏览型号5962-9760101HXC的Datasheet PDF文件第8页浏览型号5962-9760101HXC的Datasheet PDF文件第9页  
ADDC02803SC/ADDC02805SA  
PIN DESCRIPTIONS  
ABSOLUTE MAXIMUM RATINGS*  
INHIBIT . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V dc, –0.5 V dc  
SYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.0 V dc, –0.5 V dc  
ISHARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 V dc, –0.5 V dc  
TEMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 V dc, –0.3 V dc  
Common-Mode Voltage, Input to Output . . . . . . . . . 500 V dc  
Lead Soldering Temp (10 sec) . . . . . . . . . . . . . . . . . . . +300°C  
Storage Temperature . . . . . . . . . . . . . . . . . . –65°C to +150°C  
Maximum Junction Temperature . . . . . . . . . . . . . . . . +150°C  
Maximum Case Operating Temperature . . . . . . . . . . . +125°C  
Pin  
No. Name  
Function  
1
–SENSE Feedback loop connection for remote sensing  
output voltage. Must always be connected to  
output return for proper operation.  
+SENSE Feedback loop connection for remote sensing  
output voltage. Must always be connected to  
+VOUT for proper operation.  
2
*Absolute maximum ratings are limiting values, to be applied individually, and  
beyond which the serviceability of the circuit may be impaired. Functional  
operability under any of these conditions is not necessarily implied. Exposure of  
absolute maximum rating conditions for extended periods of time may affect  
device reliability.  
3
4
ADJUST Adjusts output voltage setpoint.  
STATUS Indicates output voltage is within ±5% of  
nominal. Active high referenced to –SENSE  
(Pin 1).  
5
6
7
8
VAUX  
Low level dc auxiliary voltage supply refer-  
enced to input return (Pin 10).  
ORDERING INFORMATION  
INHIBIT Power Supply Inhibit. Active low and refer-  
Operating  
Temperature  
Range (Case) Description  
enced to input return (Pin 10).  
Clock synchronization input for multiple  
units; referenced to input return (Pin 10).  
Current share pin which allows paralleled  
units to share current typically within ±5% at  
full load; referenced to input return (Pin 10).  
Device  
SYNC  
ISHARE  
ADDC02803SCKV  
ADDC02803SCTV  
5962-9760101HXC  
–40°C to +85°C Hermetic Package  
–55°C to +90°C Hermetic Package  
(ADDC2803SCTV/QMLH) –55°C to +125°C Hermetic Package  
9
TEMP  
Case temperature indicator and temperature  
shutdown override; referenced to input return  
(Pin 10).  
Input Return.  
+28 V Nominal Input Bus.  
+5 V dc Output (ADDC02805SA).  
+3.3 V dc Output (ADDC02803SC).  
+5 V dc Output (ADDC02805SA).  
+3.3 V dc Output (ADDC02803SC).  
+5 V dc Output (ADDC02805SA).  
+3.3 V dc Output (ADDC02803SC).  
ADDC02805SAKV  
ADDC02805SATV  
5962-9570701HXC  
–40°C to +85°C Hermetic Package  
–55°C to +90°C Hermetic Package  
10  
11  
12  
–VIN  
+VIN  
+VOUT  
(ADDC2805SATV/QMLH) –55°C to +125°C Hermetic Package  
EXPLANATION OF TEST LEVELS  
Test Level  
13  
14  
+VOUT  
+VOUT  
I
100% production tested.  
II  
100% production tested at +25°C, and sample tested at  
specified temperatures.  
15  
16  
17  
RETURN Output Return.  
RETURN Output Return.  
RETURN Output Return.  
III – Sample tested only.  
IV – Parameter is guaranteed by design and characterization  
testing.  
V
Parameter is a typical value only.  
PIN CONFIGURATION  
VI – All devices are 100% production tested at +25°C. 100%  
production tested at temperature extremes for military  
temperature devices; guaranteed by design and charac-  
terization testing for industrial devices.  
1
17  
12  
TOP  
VIEW  
11  
CAUTION  
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily  
accumulate on the human body and test equipment and can discharge without detection.  
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss  
of functionality.  
WARNING!  
ESD SENSITIVE DEVICE  
REV. A  
–3–