4.4.1 Group A inspection.
a. Tests shall be as specified in table II herein.
b. Subgroups 5, 6, and 8 in table I, method 5005 of MIL-STD-883 shall be omitted.
c. For device class M, subgroups 7 tests shall be sufficient to verify the truth table. For device classes Q and V,
subgroups 7 shall include verifying the functionality of the device.
TABLE II. Electrical test requirements.
Subgroups
Subgroups
(in accordance with
(in accordance with
MIL-PRF-38535, table III)
Test requirements
MIL-STD-883,
method 5005, table I)
Device
Device
class Q
Device
class V
class M
Interim electrical
1
1
1
parameters (see 4.2)
Final electrical
1, 2, 3 1/
1, 2, 3 1/
1, 2, 3 1/
parameters (see 4.2)
Group A test
1, 2, 3, 4, 7, 9, 10, 11 1, 2, 3, 4, 7, 9, 1, 2, 3, 4, 7, 9,
2/
10, 11 2/
10, 11 2/
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
1
1
1
1
1
1
- - -
- - -
- - -
1/ PDA applies to subgroup 1.
2/ Subgroups 4, 9, 10, and 11, not tested, but shall be guaranteed to the limits specified in table I herein.
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table II herein.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
a. Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MIL-STD-883.
b. TA = +125°C, minimum.
c. Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature,
or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The
test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-