ABSOLUTE MAXIMUM RATINGS
Table 5.
Parameter1
Supply Voltage
Input Voltage2
Differential Input Voltage2
Output Short-Circuit Duration
Storage Temperature Range
Operating Temperature Range
OP249A (Q)
OP249F (Q)
OP249G (N, R)
Junction Temperature Range
OP249A (Q), OP249F (Q)
OP249G (N, R)
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Rating
18 V
18 V
36 V
Indefinite
−65°C to +175°C
Table 6. Thermal Resistance
−55°C to +125°C
−40°C to +85°C
−40°C to +85°C
1
Package Type
8-Lead CERDIP (Q)
8-Lead PDIP (N)
8-Lead SOIC (R)
θJA
134
96
θJC
12
37
41
Unit
°C/W
°C/W
°C/W
150
−65°C to +175°C
−65°C to +150°C
300°C
1 θJA is specified for worst-case mounting conditions, that is, θJA is specified for
device in socket for CERDIP and PDIP packages; θJA is specified for device
soldered to printed circuit board for SOIC package.
Lead Temperature (Soldering, 60 sec)
1 Absolute maximum ratings apply to packaged parts, unless otherwise noted.
2 For supply voltages less than 18 V, the absolute maximum input voltage is
equal to the supply voltage.
ESD CAUTION
Rev. I | Page 6 of 18