4. VERIFICATION  
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535,  
appendix A.  
4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices  
prior to quality conformance inspection. The following additional criteria shall apply:  
a. Burn-in test, method 1015 of MIL-STD-883.  
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level  
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify  
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method  
1015 of MIL-STD-883.  
(2) TA = +125°C, minimum.  
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter  
tests prior to burn-in are optional at the discretion of the manufacturer.  
c. Optional subgroup 12 is used for grading the part selection at +25°C, it is not included in PDA.  
4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-  
883 including groups A, B, C, and D inspections. The following additional criteria shall apply.  
4.3.1 Group A inspection.  
a. Tests shall be as specified in table II herein.  
b. Subgroups 4, 5, 6, 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted.  
c. Optional subgroup 12 is used for grading the part selection at +25°C.  
4.3.2 Groups C and D inspections.  
a. End-point electrical parameters shall be as specified in table II herein.  
b. Steady-state life test conditions, method 1005 of MIL-STD-883.  
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision  
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall  
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in  
method 1005 of MIL-STD-883.  
(2) TA = +125°C, minimum.  
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.  
SIZE  
STANDARD  
5962-89824  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43218-3990  
REVISION LEVEL  
C
SHEET  
6
DSCC FORM 2234  
APR 97