AD589–SPECIFICATIONS
(Typical @ IIN = 500 A and TA = 25
C, unless otherwise noted.)
AD589JH/
AD589JR
Model
AD589KH
AD589LH
AD589MH
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Unit
OUTPUTVOLTAGE,TA = 25°C
1.200 1.235 1.250
1.200 1.235 1.250
1.200 1.235 1.250 1.200 1.235 1.250
V
OUTPUTVOLTAGE CHANGE
VERSUS CURRENT
50 A to 5 mA
5
5
5
5
mV
DYNAMIC OUTPUT IMPEDANCE
0.6
5
0.6
5
0.6
5
0.6
5
RMS NOISEVOLTAGE
10 Hz < f < 10 kHz
V
TEMPERATURE COEFFICIENT1
TURN-ON SETTLINGTIMETO 0.1%
OPERATING CURRENT2
100
50
25
10
ppm/°C
s
25
25
25
25
0.05
5
0.05
5
0.05
5
0.05
5
°C
OPERATINGTEMPERATURE
0
70
0
70
0
70
0
70
PACKAGE OPTION3
Metal Can (H-02A)
SOIC (R-8)
AD589JH
AD589JR
AD589KH
AD589LH
AD589MH
Min
Typ Max
Min
Typ Max Unit
OUTPUTVOLTAGE,TA = 25°C
1.200 1.235 1.250
1.200 1.235 1.250
V
OUTPUTVOLTAGE CHANGE
VERSUS CURRENT
50 A to 5 mA
5
5
mV
DYNAMIC OUTPUT IMPEDANCE
0.6
5
2
0.6
5
2
RMS NOISEVOLTAGE
10 Hz < f < 10 kHz
V
TEMPERATURE COEFFICIENT1
TURN-ON SETTLINGTIMETO 0.1%
OPERATING CURRENT2
100
50
ppm/°C
s
25
25
0.05
5
0.05
5
mA
°C
OPERATINGTEMPERATURE
–55
+125
–55
+125
PACKAGE OPTION3
Metal Can (H-02)
SOIC (R-8)
AD589SH
AD589JR
AD589TH
NOTES
1See theVoltageVariation versusTemperature section for explanation of temperature coefficient measurement method.
2Optimum performance is obtained at currents below 500 A. For current operation below 200 A, stray shunt capacitances should be limited to 20 pF or increased to
1 F. If strays cannot be avoided, operation at 500 A and a shunt capacitor of at least 1000 pF are recommended.
3H = Hermetic Metal Can; R = SOIC.
Specifications shown in boldface are tested on all production units at final electrical test.
Specifications subject to change without notice.
REV. C