3B42 / 3B43 / 3B44
3B42, 3B43 and 3B44 Models Available
Model
Input Range
Output Ranges1
0 V to +10 V & 0 mA to 20 mA
0 V to +10 V & 0 mA to 20 mA
0 V to +10 V & 0 mA to 20 mA
*
3B42-00
3B42-01
Externally Programmable2
0 mV to +50 mV rms
0 mV to +100 mV rms
*
3B42-02
3B42-Custom
Model
Input Range
Output Ranges1
3B43-00
Externally Programmable2
0 V to +10 V rms
*
0 V to +10 V & 0 mA to 20 mA
0 V to +10 V & 0 mA to 20 mA
*
3B43-01
3B43-Custom
Model
Input Range
Output Ranges1
3B44-00
Externally Programmable2
0 V to +150 V rms
0 V to +250 V rms
*
0 V to +10 V & 0 mA to 20 mA
0 V to +10 V & 0 mA to 20 mA
0 V to +10 V & 0 mA to 20 mA
*
3B44-01
3B44-02
3B44-Custom
1 Output current range may be user programmed to 4 mA to 20 mA using jumper supplied.
2 Requires AC1310 ranging card.
* Custom Input/Output ranges are available. Refer to configuration guide.
3B42, 3B43 and 3B44 Specifications
(typical @ +25°C and ±15 V dc, and +24 V dc Power)
Description
Model 3B42
Model 3B43
Model 3B44
Input Ranges
Standard Ranges, 50 Hz to 400 Hz
Custom Ranges, 50 Hz to 400 Hz
Refer to Model Table
Refer to Model Table
1 V rms to 50 V rms
Refer to Model Table
50 V rms to 550 V rms
20 mV rms to 1 V rms
Output Ranges
0 V to +10 V
*
*
*
*
Voltage (RL > 2 kΩ)
Current (RL + 0 to 850 Ω)1
4 mA to 20 mA or 0 mA to 20 mA
Accuracy2
Initial @ +25°C
Nonlinearity
±0.05% Span
±0.02% Span
*
*
*
*
Stability vs. Temperature
Voltage Output
Zero
±0.005% of Span/°C
*
*
*
*
Span
±0.005% of Reading/°C
Current Output3
Zero
±25 ppm of Span/°C
±25 ppm of Reading/°C
±5% of Span
*
*
*
*
*
*
Span
Zero and Span Adjustment Range4
Rev. 0 | Page 3 of 8