欢迎访问ic37.com |
会员登录 免费注册
发布采购

3B37-J-01 参数 Datasheet PDF下载

3B37-J-01图片预览
型号: 3B37-J-01
PDF下载: 下载PDF文件 查看货源
内容描述: 隔离,热电偶输入 [Isolated, Thermocouple Input]
分类和应用:
文件页数/大小: 8 页 / 336 K
品牌: ADI [ ADI ]
 浏览型号3B37-J-01的Datasheet PDF文件第1页浏览型号3B37-J-01的Datasheet PDF文件第2页浏览型号3B37-J-01的Datasheet PDF文件第3页浏览型号3B37-J-01的Datasheet PDF文件第5页浏览型号3B37-J-01的Datasheet PDF文件第6页浏览型号3B37-J-01的Datasheet PDF文件第7页浏览型号3B37-J-01的Datasheet PDF文件第8页  
3B37  
Input Resistance  
15 MΩ  
Noise  
Input, 0.1 Hz to 10 Hz Bandwidth  
Output, 100 kHz Bandwidth  
Bandwidth, -3 dB  
0.2 µV rms  
50 µV rms  
3 Hz  
200 ms  
Output Rise Time, 10% to 90% Span  
Open Input Response  
Upscale  
Open Input Detection Time  
10 seconds  
Common-Mode Voltage (CMV)  
Input-to-Output, Continuous  
Transient  
±1500 V peak, maximum  
ANSI/IEEE C37.90.1-1989  
Common Mode Rejection (CMR)  
160 dB  
60 dB  
1 kSource Imbalance, 50/60 Hz  
Normal Mode Rejection, 50/60 Hz  
Input Protection  
Continuous  
220 V rms maximum  
Transient  
ANSI/IEEE C37.90.1-1989  
Continuous Short to Ground  
130 V rms, continuous  
Voltage Output Protection  
Current Output Protection  
Power Supply Voltages 6  
±15 V dc Supplies  
Rated Operation  
Current  
±(11.5 V dc to 16.5 V dc)  
±12 mA  
Sensitivity  
±0.01% span/V  
+24 V dc Loop Supply  
Rated Operation  
Current  
+12 V dc to +30 V dc  
+27 mA @ lout = 20 mA  
±0.0002% span/V  
Sensitivity  
Mechanical Dimensions  
3.15" x 3.395" x 0.775"  
(80.0 mm x 86.2 mm x 19.7 mm)  
Environmental  
Temperature Range  
Rated Performance  
Storage  
-25°C to +85°C  
-55°C to +85°C  
Relative Humidity, 24 hours  
RFI Susceptibility  
0 to 95% @ +60°C noncondensing  
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft  
1 For a 0 mA to 20 mA range, a typical minimum output current is 10 µA.  
2 Includes the combined effects of repeatability, hysteresis, and nonlinearity.  
3 With respect to the voltage output.  
4 A wide range of custom zero suppression and span is available with the 3B30-00 and 3B31-00 models, using the AC1310 ranging card.  
5 When used with the CJC temperature sensor provided on the 3B Series backplane.  
6 +24 V dc loop power is required for driving the current output at loads up to 850. If a current output load of 400or less is applied, +15 V dc is sufficient for loop power. If only  
voltage output is used, loop power is not required.  
Rev. 0 | Page 4 of 8