3B20  
GENERAL DESCRIPTION  
selecting resistors, a Windows program, 3B-CUSTOM,  
calculates resistor values based on the user-desired input/output  
ranges.  
The 3B20 is a wideband single-channel signal-conditioning  
module which interfaces 4-arm AC bridge transducer signals  
ranging between 1.5mV rms and 150mV rms, providing  
simultaneous precision voltage and current outputs. In addition,  
the module provides an AC excitation voltage of 2V rms to 10V  
rms at frequencies between 1kHz and 10kHz. The module  
withstands 130V rms at its current output terminals without  
damage thereby shielding computer-side circuitry from field-  
side over-voltage conditions. The 3B20 is a plug-in, mix-and-  
match, hot-swappable module and is easily field calibrated via  
front-panel zero and span adjustments for both voltage and  
current outputs.  
The 3B20 input and AC bridge excitation output terminals are  
protected for up to 130V rms. The excitation amplitude and  
frequency can be specified with the Model 3B20 CUSTOM or  
user configured with Model 3B20-00 and an optional plug-on  
Model AC1310 ranging card. Both the voltage and current  
outputs can be independently adjusted for a minimum of +1V  
for the zero and 25% of the span range with front-panel user-  
accessible potentiometers. In addition, phase shifts of up to  
37.25o between excitation signal and the output signal from the  
strain gauge or torque transducer can be compensated via front-  
panel screw terminal adjustments.  
3B Series Custom-Ranging Program – Externally-  
programmable Model 3B20-00, enables the user to configure a  
special input range, including tare weight suppression, by using  
the optional plug-on AC1310 ranging card, which houses user-  
supplied resistors to determine zero and span. To facilitate  
.
.
Figure 2  
Rev. 0 | Page 2 of 8