3B16  
Vexc= +10.0 V  
300 to 1 kΩ  
±5% of Span  
Zero and Span Adjustment Range4  
Input Bias Current  
+3 nA  
Input Resistance  
100 MΩ  
Noise  
Input, 0.1 Hz to 10 Hz Bandwidth  
Output, 100 kHz Bandwidth  
Bandwidth, -3 dB  
0.2 µV rms  
50 µV rms  
3 Hz  
Output Rise Time, 10% to 90% Span  
200 ms  
Common-Mode Voltage (CMV)  
±10 V peak, maximum  
ANSI/IEEE C37.90.1-1989  
60 dB  
Input-to-Output, Continuous  
Transient  
Normal Mode Rejection @ 50/60 Hz  
Input Protection, Signal and Excitation Voltage  
130 V rms maximum  
ANSI/IEEE C37.90.1-1989  
Continuous Short to Ground  
130 V rms, continuous  
Power Supply Voltages 5  
Continuous  
Trasient  
Voltage Output Protection  
Current Output Protection  
±15 V dc Supplies  
Rated Operation  
Current  
±(12.7 V dc to 16.5 V dc)  
+45 mA, -10 mA  
Sensitivity  
±0.01% span/V  
+24 V dc Loop Supply  
Rated Operation  
Current  
+12 V dc to +30 V dc  
+27 mA @ lout = 20 mA  
±0.0002% span/V  
Sensitivity  
Mechanical Dimensions  
3.15" x 3.395" x 0.775"  
80.0 mm x 86.2 mm x 19.7 mm)  
Environmental  
Temperature Range  
Rated Performance  
Storage  
-25°C to +85°C  
-55°C to +85°C  
Relative Humidity, 24 hours  
RFI Susceptibility  
0 to 95% @ +60°C noncondensing  
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft  
1 For a 0 mA to 20 mA range, a typical minimum output current is 10 µA.  
2 Includes the combined effects of repeatability, hysteresis, and nonlinearity.  
3 With respect to the voltage output.  
4 A wide range of custom zero suppression and span is available with the 3B16-00 model, using the AC1310 ranging card.  
5 +24 V dc loop power is required for driving the current output at loads up to 850. If a current output load of 400or less is applied, +15 V dc is sufficient for loop power. If only  
voltage output is used, loop power is not required.  
Specifications subject to change without notice.  