ADR1581
SPECIFICATIONS
TA = 25°C, IIN = 100 ꢀA, unless otherwise noted.
Table 1.
ADR1±81A
Typ
ADR1±81B
Typ
Parameter
Min
Max
Min
Max
Unit
REVERSE VOLTAGE OUTPUT (SOT-23)
REVERSE VOLTAGE TEMPERATURE DRIFT
−40°C to +85°C
1.240
1.250
1.260
1.2485
1.250
1.2515
V
100
60
50
60
ppm/°C
μA
MINIMUM OPERATING CURRENT, TMIN to TMAX
REVERSE VOLTAGE CHANGE WITH REVERSE CURRENT
60 μA < IIN < 10 mA, TMIN to TMAX
60 μA < IIN < 1 mA, TMIN to TMAX
DYNAMIC OUTPUT IMPEDANCE (∆VR/ΔIR)
IIN = 1 mA 100 μA (f = 120 Hz)
OUTPUT NOISE
2.5
0.8
6
1
2.5
0.8
6
mV
mV
0.4
0.4
0.5
Ω
RMS Noise Voltage: 10 Hz to 10 kHz
Low Frequency Noise Voltage: 0.1 Hz to 10 Hz
TURN-ON SETTLING TIME TO 0.1%1
OUTPUT VOLTAGE HYSTERESIS2
TEMPERATURE RANGE
20
4.5
5
20
4.5
5
μV rms
μV p-p
ꢀs
80
80
ꢀV
Specified Performance, TMIN to TMAX
Operating Range3
−40
−55
+85
+125
−40
−55
+85
+125
°C
°C
1 Measured with a no load capacitor.
2 Output hysteresis is defined as the change in the +25°C output voltage after a temperature excursion to −40°C, then to +85°C, and back to +25°C.
3 The operating temperature range is defined as the temperature extremes at which the device continues to function. Parts may deviate from their specified
performance.
Rev. 0 | Page 3 of 12