HMC674LC3C/HMC674LP3E
Data Sheet
ABSOLUTE MAXIMUM RATINGS
Table 7.
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Parameter
Rating
Supply Voltage
Input (VCCI to GND)
Output (VCCO to GND)
Positive Differential (VCCI to VCCO
VEE Supply to GND
Input Voltage
−0.5 V to +4 V
−0.5 V to +4 V
−0.5 V to +3.3 V
−3.3 V to +0.5 V
−2 V to +2 V
)
Differential
−2 V to +2 V
−0.5 V to VCCI + 0.5 V
VEE to GND
ESD CAUTION
Latch Enable (LE/LE)
Applied Voltage (HYS)
Current
Maximum Input
Output
20 mA
40 mA
Continuous Power Dissipation (PDISS), TA = 85°C
Derate 43.5 mW/°C Above 85°C
(HMC674LP3E)
Derate 20.4 mW/°C Above 85°C
(HMC674LC3C)
Junction Temperature
Maximum Peak Reflow Temperature1
1.74 W
0.816 W
125°C
MSL1 and MSL3
260°C
Thermal Resistance (θJC)
HMC674LP3E
23°C/W
HMC674LC3C
49°C/W
Storage Temperature Range
Operating Temperature Range
ESD Sensitivity, Human Body Model (HBM)
−65°C to +150°C
−40°C to +85°C
Class 1A
1 See the Ordering Guide section.