Data Sheet
HMC546LP2E
SPECIFICATIONS
TA = 25°C, VDD = 0 V/3 V dc, VCTL = 0 V/3 V dc, 50 Ω system. Specifications and data reflect measurements using the respective
application circuit components for each frequency band as listed in Table 1.
Table 1.
Parameter
Symbol Test Conditions/Comments
Min Typ Max Unit
FREQUENCY RANGE
INSERTION LOSS
Tx to RFC
200
2700 MHz
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
0.3
0.4
0.6
0.5
0.4
0.3
1.1
0.7
0.6
0.7
0.8
0.8
0.7
0.6
1.5
1.1
dB
dB
dB
dB
dB
dB
dB
dB
RFC to Rx
ISOLATION
Tx to RFC
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
15
14
15
10
22
20
25
30
23
22
20
15
30
27
30
40
dB
dB
dB
dB
dB
dB
dB
dB
RFC to Rx
RETURN LOSS
Tx to RFC
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
25
20
22
20
25
25
10
12
dB
dB
dB
dB
dB
dB
dB
dB
RFC to Rx
INPUT LINEARITY
0.1 dB Power Compression
Tx to RFC
P0.1dB
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
38
39
40
41
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
36.5 38.5
38.5 40.5
19
19
17
18
RFC to Rx
21
21
19
20
Input Third-Order Intercept
Tx to RFC
IP3
Two-tone input power = 19 dBm/tone, ∆f = 1 MHz
f = 1805 MHz to 1910 MHz
f = 2010 MHz to 2025 MHz
f = 2300 MHz to 2480 MHz
f = 2500 MHz to 2700 MHz
65
64
67
62
dBm
dBm
dBm
dBm
Rev. E | Page 3 of 13