欢迎访问ic37.com |
会员登录 免费注册
发布采购

AQ112CY-S4-AJ-TR 参数 Datasheet PDF下载

AQ112CY-S4-AJ-TR图片预览
型号: AQ112CY-S4-AJ-TR
PDF下载: 下载PDF文件 查看货源
内容描述: 超低压差1A稳压器 [Ultra-Low Dropout 1A Voltage Regulator]
分类和应用: 稳压器
文件页数/大小: 10 页 / 619 K
品牌: ACUTECH [ ACUTECHNOLOGY SEMICONDUCTOR ]
 浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第1页浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第2页浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第3页浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第5页浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第6页浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第7页浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第8页浏览型号AQ112CY-S4-AJ-TR的Datasheet PDF文件第9页  
Acutechnology Semiconductor Inc.
AQ112
Electrical Specifications
Electrical characteristics are guaranteed over the full temperature range 0ºC <Tj< 125ºC. Ambient temperature
must be de-rated based upon power dissipation and package thermal characteristics. Unless otherwise
specified: V
IN
= V
EN
= (V
OUT
+ 1.5V), I
OUT
= 10 mA, Tj = 25C. All values in
bold
are over the full temperature
range.
Symbol
VOUT
LNREG
LDREG
Parameter
Output Voltage
(1)
Line Regulation
(1)
Load Regulation
(1)
Conditions
Min
-1
0°C
≤Tj ≤
125°C
∆V
IN
= V
OUT
+ (1.5V to 10V)
∆I
OUT
= (10mA to 1 Amp)
I
OUT
= 100 mA
VD
Drop out Voltage
(1, 2)
I
OUT
= 500 mA
I
OUT
= 1A
ISC
IQ
VIL
VIH
I
EN
ON
Current Limit
(1)
Quiescent Current
Enable Pin Voltage (OFF)
Enable Pin Voltage (ON)
Enable Current ON
V
EN
-V
OUT
= 2V
V
EN
= 5V
0°C
≤Tj ≤
125°C
With respect to GND
With respect to V
OUT
I
OUT
= 10 mA
I
OUT
= 500 mA
I
OUT
= 1A
VADJ
IADJ
IADJ
I
QMIN
TC
TS
V
N
PSRR
TSD
TSD
HYST
Reference Voltage
Adjust Pin Current (5)
Adjust Pin Current (5)
Change
Minimum Load Current (5)
Temperature Coefficient
Temperature Stability
RMS Output Noise
(3)
Ripple Rejection Ratio
(4)
Thermal Shutdown
TSD Hysteresis
Vin = 5V
Junction Temperature
60
10mA
I
OUT
1Amp
1.4
V
IN
18V
To Maintain regulation
Note (5)
0°C
≤Tj ≤
125°C
1.208
1.202
20
0.2
0.5
0.005
0.5
0.003
72
150
25
0.25
0.45
0.92
0.3
2.5
5.0
1.220
0.95
0.5
5.0
10.0
1.232
1.238
40
5.0
2.0
1.1
-1.5
Typ
V
OUT
V
OUT
0.035
0.2
50
200
350
1.5
7.0
9.0
10.0
Max
+1
+1.5
0.2
0.4
80
250
400
Units
%
%
%
%
mV
mV
mV
A
mA
mA
V
V
mA
mA
mA
V
V
µA
µA
mA
%/°C
%/°C
%
V
OUT
dB
°C
°C
Notes:
(1) Low duty cycle pulse testing with Kelvin connections required.
(2) Measure (V
IN
- V
OUT
) when
∆V
OUT
,
OR
∆V
REF
= 1%
(3) Bandwidth of 10Hz to 10kHz
(4) 120Hz input ripple
(5) Adjustable version only
www.acutechnology.com