PAC5255
Power Application Controller
6. ABSOLUTE MAXIMUM RATINGS
Table 3. Absolute Maximum Ratings
(Do not exceed these limits to prevent damage to the device. Exposure to absolute maximum rating conditions for long periods may affect device
reliability.)
PARAMETER
VALUE
-0.3 to 54
-0.3 to 20
-0.3 to VP + 0.3
-0.3 to 6
UNIT
V
VHM, DRM to VSSP
VP to VSS
V
CSM, REGO to VSS
VSYS, AIO6/.. to VSS
VCC33 to VSS
V
V
-0.3 to 4.1
-0.3 to 2.5
-0.3 to VSYS + 0.3
-0.3 to VCCIO + 0.3
-0.3 to VCC18 + 0.3
-0.3 to VCC33 + 0.3
-0.3 to VP + 0.3
-0.3 to 630
-11 to 610
-50 to 50
V
VCC18 to VSS
V
AIOx/.. (except AIO6/..), VCCIO, CLKOUT/ENHS2 to VSS
PDx/.., PEx/.. to VSS
V
V
XIN, XOUT to VSS
V
PCx/.. to VSSA
V
DRLx to VSSP
V
DXBx to VSSP
V
DXSx to VSSP
V
DXSx allowable offset slew rate (dVDXSx/dt)
DXBx, DXHx to respective DXSx
OMx to VSSP
V/ns
V
-0.3 to 22
-0.3 to 24
-0.3 to 0.3
0.2
V
VSSP, VSSA to VSS
V
VSS, VSYS, DRM, DRLx, DXHx, REGO, OMx RMS current(1)
VSSP RMS current(1)
ARMS
ARMS
ARMS
°C
kV
V
0.4
VP RMS current(1)
0.6
Operating temperature range
-40 to 105
2
Human body model (JEDEC)
Electrostatic discharge (ESD)
Charge device model (JEDEC)
800
Machine model (JEDEC)
200
V
(1) Peak current can be 10 times higher than RMS value for pulses shorter than 10µs.
- 12 -
Rev 1.10‒March 3, 2018