 浏览型号ACT8946AQJ203-T的Datasheet PDF文件第29页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第30页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第31页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第32页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第34页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第35页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第36页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第37页  
ACT8946AQJ203-T  
Rev 1.0, 08-Jul-16  
temperature is inside of the valid range, a value of 0  
indicates the battery is outside of the valid range.  
END-OF-CHARGE (EOC) State  
In the END-OF-CHARGE (EOC) state, the charger  
presents high-impedance to the battery,  
minimizing battery current drain and allowing the  
cell to relax”. The charger continues to monitor the  
cell voltage, and re-initiates a charging sequence if  
the cell voltage drops to 205mV (typ) below the  
charge termination voltage.  
a
When an interrupt is generated by the battery  
temperature event, reading the TEMPSTAT[ ]  
returns a value of 1. TEMPSTAT[ ] is automatically  
cleared to 0 upon reading. When no interrupt is  
generated by the battery temperature event,  
reading the TEMPSTAT[ ] returns a value of 0.  
SUSPEND State  
Charge-Control State Machine  
The state-machine jumps to the SUSPEND state  
any time the battery is removed, and any time the  
input voltage either falls below the CHGIN UVLO  
threshold or exceeds the OVP threshold. Once  
none of these conditions are present, a new charge  
cycle initiates.  
PRECONDITION State  
A
new charging cycle begins with the  
PRECONDITION state, and operation continues in  
this state until VBAT exceeds the Precondition  
Threshold  
Voltage.  
When  
operating  
in  
PRECONDITION state, the cell is charged at 10%  
of the programmed maximum fast-charge constant  
A charging cycle may also be suspended manually  
by setting the SUSPEND[ ] bit. In this case, initiate  
a new charging sequence by clearing SUSPEND[ ]  
to 0.  
current, ICHG  
.
Once VBAT reaches the Precondition Threshold  
Voltage, the state machine jumps to the FAST-  
CHARGE state. If VBAT does not reach the  
Precondition Threshold Voltage before the  
Precondition Time-out period expires, then the state  
machine jumps to the TIME-OUT-FAULT state in  
order to prevent charging a damaged cell. See the  
Charge Safety Timers section for more information.  
State Machine Interrupts  
The charger features the ability to generate  
interrupts when the charger state machine  
transitions, based upon the status of the CHG_ bits.  
Set CHGEOCIN[ ] bit to 1 and CHGSTAT[ ] bit to 1  
to generate an interrupt when the charger state  
machine goes into the END-OF-CHARGE (EOC)  
state. Set CHGEOCOUT[ ] bit to 1 and CHGSTAT[ ]  
bit to 1 to generate an interrupt when the charger  
state machine exits the EOC state.  
FAST-CHARGE State  
In the FAST-CHARGE state, the charger operates  
in constant-current (CC) mode and regulates the  
charge current to the current set by RISET . Charging  
continues in CC mode until VBAT reaches the charge  
termination voltage (VTERM), at which point the state-  
machine jumps to the TOP-OFF state. If VBAT does  
not reach VTERM before the total time out period  
expires then the state-machine will jump to the  
EOCstate and will re-initiate a new charge cycle  
after 32ms relax”. See the Current Limits and  
Charge Current Programming sections for more  
information about setting the maximum charge  
current.  
CHGDAT[ ] indicates the status of the charger state  
machine. A value of 1 indicates that the charger  
state machine is in END-OF-CHARGE state, a  
value of 0 indicates the charger state machine is in  
other states.  
When an interrupt is generated by the charger state  
machine, reading the CHGSTAT[ ] returns a value  
of 1. CHGSTAT[ ] is automatically cleared to 0 upon  
reading. When no interrupt is generated by the  
charger state machine, reading the CHGSTAT[ ]  
returns a value of 0.  
TOP-OFF State  
For additional information about the charge cycle,  
CSTATE[1:0] may be read at any time via I2C to  
determine the current charging state.  
In the TOP-OFF state, the cell charges in constant-  
voltage (CV) mode. In CV mode operation, the  
charger regulates its output voltage to the 4.20V  
charge termination voltage, and the charge current  
is naturally reduced as the cell approaches full  
charge. Charging continues until the charge current  
drops to END-OF-CHARGE current threshold, at  
which point the state machine jumps to the END-  
OF-CHARGE (EOC) state.  
Table 11: Charging Status Indication  
CSTATE[1] CSTATE[0] STATE MACHINE STATUS  
1
1
1
0
PRECONDITION State  
FAST-CHARGE/  
TOP-OFF State  
If the state-machine does not jump out of the TOP-  
OFF state before the Total-Charge Time-out period  
expires, then the state machine jumps to the EOC  
state and will re-initiate a new charge cycle if VBAT  
falls below termination voltage 205mV (typ). For  
more information about the charge safety timers,  
see the Charging Safety Times section.  