 浏览型号ACT8946AQJ203-T的Datasheet PDF文件第11页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第12页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第13页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第14页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第16页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第17页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第18页浏览型号ACT8946AQJ203-T的Datasheet PDF文件第19页  
ACT8946AQJ203-T  
Rev 1.0, 08-Jul-16  
REGISTER AND BIT DESCRIPTIONS CONTD  
OUTPUT ADDRESS BIT  
NAME  
ACCESS  
DESCRIPTION  
Temperature Status. Value is 0 when battery temperature is  
outside of valid range. Value is 1 when battery temperature  
is inside of valid range.  
APCH  
APCH  
APCH  
0x78  
0x78  
0x78  
[2]  
[1]  
[0]  
TEMPDAT  
R
Input Voltage Status. Value is 1 when a valid input at  
CHGIN is present. Value is 0 when a valid input at CHGIN  
is not present.  
INDAT  
R
R
Charge State Machine Status. Value is 1 indicates the  
charger state machine is in EOC state, value is 0 indicates  
the charger state machine is in other states.  
CHGDAT  
Total Charge Time-out Interrupt Control. Set both this bit  
and TIMRSTAT[ ] to 1 to generate an interrupt when a total  
charge time-out occurs. See the Charge Safety Timers  
section for more information.  
APCH  
APCH  
APCH  
APCH  
APCH  
APCH  
APCH  
APCH  
0x79  
0x79  
0x79  
0x79  
0x79  
0x79  
0x79  
0x79  
[7]  
[6]  
[5]  
[4]  
[3]  
[2]  
[1]  
TIMRTOT  
TEMPIN  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Battery Temperature Interrupt Control. Set both this bit and  
TEMPSTAT[ ] to 1 to generate an interrupt when the battery  
temperature goes into the valid range. See the Battery  
Temperature Monitoring section for more information.  
Input Voltage Interrupt Control. Set both this bit and  
INSTAT[ ] to 1 to generate an interrupt when CHGIN input  
voltage goes into the valid range. See the Charge Current  
Programming section for more information.  
INCON  
Charge State Interrupt Control. Set both this bit and  
CHGSTAT[ ] to 1 to generate an interrupt when the state  
machine goes into the EOC state. See the State Machine  
Interrupts section for more information.  
CHGEOCIN  
TIMRPRE  
TEMPOUT  
INDIS  
PRECHARGE Time-out Interrupt Control. Set both this bit  
and TIMRSTAT[ ] to 1 to generate an interrupt when a  
PRECHARGE time-out occurs. See the Charge Safety  
Timers section for more information.  
Battery Temperature Interrupt Control. Set both this bit and  
TEMPSTAT[ ] to 1 to generate an interrupt when the battery  
temperature goes out of the valid range. See the Battery  
Temperature Monitoring section for more information.  
Input Voltage Interrupt Control. Set both this bit and  
INSTAT[ ] to 1 to generate an interrupt when CHGIN input  
voltage goes out of the valid range. See the Charge Current  
Programming section for more information.  
Charge State Interrupt Control. Set both this bit and  
CHGSTAT[ ] to 1 to generate an interrupt when the state  
machines jumps out of the EOC state. See the State  
Machine Interrupts section for more information.  
[0] CHGEOCOUT  
APCH  
APCH  
APCH  
0x7A  
0x7A  
0x7A  
[7:6]  
[5:4]  
[3:2]  
-
R
R
R
Reserved.  
Charge State. Values indicate the current charging state.  
See the State Machine Interrupts section for more  
information.  
CSTATE  
-
Reserved.  
ACIN Status. Indicates the state of the ACIN input, typically  
in order to identify the type of input supply connected. Value  
is 1 when ACIN is above the 1.2V precision threshold, value  
is 0 when ACIN is below this threshold.  
APCH  
APCH  
0x7A  
0x7A  
[1]  
[0]  
ACINSTAT  
R
R
-
Reserved.  
: Valid only when CHGIN UVLO Threshold<VCHGIN<CHGIN OVP Threshold.  