 浏览型号ACT8945AQJ405-T的Datasheet PDF文件第8页浏览型号ACT8945AQJ405-T的Datasheet PDF文件第9页浏览型号ACT8945AQJ405-T的Datasheet PDF文件第10页浏览型号ACT8945AQJ405-T的Datasheet PDF文件第11页浏览型号ACT8945AQJ405-T的Datasheet PDF文件第13页浏览型号ACT8945AQJ405-T的Datasheet PDF文件第14页浏览型号ACT8945AQJ405-T的Datasheet PDF文件第15页浏览型号ACT8945AQJ405-T的Datasheet PDF文件第16页  
ACT8945A  
Rev 6, 01-Feb-16  
REGISTER AND BIT DESCRIPTIONS CONT’D  
OUTPUT ADDRESS BIT  
NAME  
ACCESS  
DESCRIPTION  
0x30  
0x30  
0x31  
0x31  
[7:6]  
[5:0]  
[7:6]  
[5:0]  
R
Reserved.  
REG2  
REG2  
REG2  
REG2  
-
Primary Output Voltage Selection. Valid when VSEL is driven  
low. See the Output Voltage Programming section for more  
information.  
VSET1  
-
R/W  
R
Reserved.  
Secondary Output Voltage Selection. Valid when VSEL is  
driven high. See the Output Voltage Programming section for  
more information.  
VSET2  
R/W  
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear  
bit to 0 to disable the regulator.  
REG2  
REG2  
0x32  
0x32  
[7]  
[6]  
ON  
R/W  
R/W  
Regulator Phase Control. Set bit to 1 for the regulator to  
operate 180° out of phase with the oscillator, clear bit to 0 for  
the regulator to operate in phase with the oscillator.  
PHASE  
Regulator Mode Select. Set bit to 1 for fixed-frequency PWM  
under all load conditions, clear bit to 0 to transit to power-  
savings mode under light-load conditions.  
REG2  
0x32  
[5]  
MODE  
R/W  
Regulator Turn-On Delay Control. See the REG1, REG2,  
REG3 Turn-on Delay section for more information.  
REG2  
REG2  
0x32  
0x32  
[4:2]  
[1]  
DELAY  
R/W  
R/W  
Regulator Fault Mask Control. Set bit to 1 enable fault-  
interrupts, clear bit to 0 to disable fault-interrupts.  
nFLTMSK  
Regulator Power-OK Status. Value is 1 when output voltage  
exceeds the power-OK threshold, value is 0 otherwise.  
REG2  
REG3  
0x32  
0x40  
[0]  
OK  
-
R
R
[7:6]  
Reserved.  
Primary Output Voltage Selection. Valid when VSEL is driven  
low. See the Output Voltage Programming section for more  
information.  
REG3  
REG3  
REG3  
0x40  
0x41  
0x41  
[5:0]  
[7:6]  
[5:0]  
VSET1  
-
R/W  
R
Reserved.  
Secondary Output Voltage Selection. Valid when VSEL is  
driven high. See the Output Voltage Programming section for  
more information.  
VSET2  
R/W  
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear  
bit to 0 to disable the regulator.  
REG3  
REG3  
0x42  
0x42  
[7]  
[6]  
ON  
-
R/W  
R/W  
Reserved.  
Regulator Mode Select. Set bit to 1 for fixed-frequency PWM  
under all load conditions, clear bit to 0 to transit to power-  
savings mode under light-load conditions.  
REG3  
0x42  
[5]  
MODE  
R/W  
Regulator Turn-On Delay Control. See the REG1, REG2,  
REG3 Turn-on Delay section for more information.  
REG3  
REG3  
REG3  
0x42  
0x42  
0x42  
[4:2]  
[1]  
DELAY  
nFLTMSK  
OK  
R/W  
R/W  
R
Regulator Fault Mask Control. Set bit to 1 enable fault-  
interrupts, clear bit to 0 to disable fault-interrupts.  
Regulator Power-OK Status. Value is 1 when output voltage  
exceeds the power-OK threshold, value is 0 otherwise.  
[0]  