ACT8942
Rev 2, 15-Nov-12
Figure 5:
Typical Li+ charge profile and ACT8942 charge states
A: PRECONDITION State
B: FAST-CHARGE State
C: TOP-OFF State
D: END-OF-CHARGE State
Figure 6:
Charger State Diagram
TEMP NOT OK
ANY STATE
(VCHGIN < VBAT) OR (VCHGIN < VCHGIN UVLO)
OR (VCHGIN > VOVP) OR (SUSCHG[ ] = 1)
SUSPEND
TEMP-FAULT
(VCHGIN > VBAT) AND (VCHGIN > VCHGIN UVLO)
AND (VCHGIN < VOVP) AND (SUSCHG[ ] = 0)
TEMP OK
PRECONDITION
TIME-OUT-FAULT
PRECONDITION
Time-out
(VBAT > 2.85V) AND
(TQUAL = 32ms)
Total Time-out
FAST-CHARGE
(VBAT = VTERM ) AND
(TQUAL = 32ms)
(VBAT < VTERM - 205mV )
AND (TQUAL = 32ms)
TOP-OFF
(IBAT < 10% x ICHG) OR (Total
Time-out) AND (TQUAL = 32ms)
END-OF-CHARGE
Innovative PowerTM
Active-Semi Proprietary―For Authorized Recipients and Customers
ActivePMUTM and ActivePathTM are trademarks of Active-Semi.
I2CTM is a trademark of NXP.
- 39 -
www.active-semi.com