 浏览型号ACT8937QJ21C-T的Datasheet PDF文件第9页浏览型号ACT8937QJ21C-T的Datasheet PDF文件第10页浏览型号ACT8937QJ21C-T的Datasheet PDF文件第11页浏览型号ACT8937QJ21C-T的Datasheet PDF文件第12页浏览型号ACT8937QJ21C-T的Datasheet PDF文件第14页浏览型号ACT8937QJ21C-T的Datasheet PDF文件第15页浏览型号ACT8937QJ21C-T的Datasheet PDF文件第16页浏览型号ACT8937QJ21C-T的Datasheet PDF文件第17页  
®
ACT8937  
Rev 0, 21-Sep-10  
REGISTER AND BIT DESCRIPTIONS CONT’D  
OUTPUT ADDRESS BIT  
NAME  
ACCESS  
DESCRIPTION  
Regulator Power-OK Status. Value is 1 when output voltage  
exceeds the power-OK threshold, value is 0 otherwise.  
REG7  
APCH  
0x65  
0x70  
[0]  
OK  
-
R
[7:0]  
R/W  
Reserved.  
Charge Suspend Control Input. Set bit to 1 to suspend  
charging, clear bit to 0 to allow charging to resume.  
APCH  
APCH  
APCH  
0x71  
0x71  
0x71  
[7]  
[6]  
SUSCHG  
-
R/W  
R/W  
R/W  
Reserved.  
Total Charge Timeout Selection. See the Charge Safety  
Timers section for more information.  
[5:4]  
TOTTIMO  
Precondition Charge Timeout Selection. See the Charge  
Safety Timers section for more information.  
APCH  
APCH  
APCH  
APCH  
APCH  
APCH  
0x71  
0x71  
0x78  
0x78  
0x78  
0x78  
[3:2]  
[1:0]  
[7]  
PRETIMO  
OVPSET  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Input Over-Voltage Protection Threshold Selection. See the  
Input Over-Voltage Protection section for more information.  
Charge Timeout Interrupt Status. See the Charge Safety  
Timers section for more information.  
TIMRSTAT  
TEMPSTAT  
INSTAT  
Temperature Interrupt Status. See the Battery Temperature  
Monitoring section for more information.  
[6]  
Input Voltage Interrupt Status. See the Charge Current  
Programming section for more information.  
[5]  
Charge State Interrupt Status. See the State Machine  
Interrupts section for more information.  
[4]  
CHGSTAT  
Charge Timer Interrupt Status. Value is 1 when precondition  
timeout or total charge timeout fault occurs. Value is 0 in  
other case.  
APCH  
APCH  
APCH  
0x78  
0x78  
0x78  
[3]  
[2]  
[1]  
TIMRDAT  
TEMPDAT  
INDAT  
R
R
R
Temperature Status. Value is 1 when battery temperature is  
outside of valid range. Value is 0 when battery temperature  
is inside of valid range.  
Input Voltage Status. Value is 1 when a valid input at  
CHGIN is present. Value is 0 when a valid input at CHGIN  
is not present.  
Charge State Status. Value is 1 when in END-OF-CHARGE  
State. Value is 0 when in other state.  
APCH  
APCH  
APCH  
APCH  
APCH  
APCH  
APCH  
APCH  
0x78  
0x79  
0x79  
0x79  
0x79  
0x79  
0x79  
0x79  
[0]  
[7]  
[6]  
[5]  
[4]  
[3]  
[2]  
[1]  
CHGDAT  
TIMRTOT  
TEMPIN  
R
Charge Timer Interrupt Control. See the Charge Safety  
Timers section for more information.  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Temperature Interrupt Control. See the Battery Temperature  
Monitoring section for more information.  
Input Voltage Interrupt Control. See the Charge Current  
Programming section for more information.  
INCON  
Charge State Interrupt Control. See the State Machine  
Interrupts section for more information.  
CHGEOCIN  
TIMRPRE  
TEMPOUT  
INDIS  
Charge Timer Interrupt Control. See the Charge Safety  
Timers section for more information.  
Temperature Interrupt Control. See the Battery Temperature  
Monitoring section for more information.  
Input Voltage Interrupt Control. See the Charge Current  
Programming section for more information.  
Charge State Interrupt Control. See the State Machine  
Interrupts section for more information.  
APCH  
APCH  
0x79  
0x7A  
[0] CHGEOCOUT  
[7:6]  
R/W  
R
-
Reserved.  
Innovative PowerTM  
www.active-semi.com  
- 13 -  
Active-Semi ProprietaryFor Authorized Recipients and Customers  
ActivePMUTM and ActivePathTM are trademarks of Active-Semi.  
I2CTM is a trademark of NXP.  
Copyright © 2010 Active-Semi, Inc.  
 复制成功!