ACT8935
Rev 4, 17-Sep-13
SYSTEM CONTROL ELECTRICAL CHARACTERISTICS
(VVSYS = 3.6V, TA = 25°C, unless otherwise specified.)
PARAMETER
Input Voltage Range
TEST CONDITIONS
MIN
2.7
TYP
MAX
5.5
UNIT
V
UVLO Threshold Voltage
UVLO Hysteresis
V
VSYS Rising
VSYS Falling
2.2
2.45
200
2.65
V
V
mV
REG1 Enabled. REG2, REG3, REG4,
REG5, REG6 and REG7 Disabled
155
260
420
REG1, REG2 and REG5 Enabled. REG3,
REG4, REG6 and REG7 Disabled
Supply Current
µA
REG1, REG2, REG3, REG4, REG5,
REG6 and REG7 Enabled
Shutdown Supply Current
Oscillator Frequency
All Regulators Disabled
8
2
18
µA
MHz
V
1.8
1.4
2.2
Logic High Input Voltage1
Logic Low Input Voltage
Leakage Current
0.4
1
V
V
V
nIRQ = VnRSTO = 4.2V
BAT Falling
µA
V
LBI Threshold Voltage
LBI Hysteresis Threshold
Low Level Output Voltage2
nRSTO Delay
1.03
1.2
1.31
VBAT Rising
ISINK = 5mA
200
mV
V
0.35
260ꢂ
160
20
ms
°C
°C
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
Temperature rising
ꢀ: PWRHLD, PWREN, EXTON are logic inputs.
2: nLBO, nPBSTAT, nIRQ, nRSTO are open drain outputs.
3: Typical value shown. Actual value may vary from 227.9ms to 291.2ms.
Innovative PowerTM
- 15 -
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.
Active-Semi Proprietary―For Authorized Recipients and Customers