ACT6357/ACT6358  
Rev 1, 15-Nov-12  
FUNCTIONAL BLOCK DIAGRAM  
where tSS is the required soft start duration. In a  
typical application, use 0.1µF to generate 20ms soft  
start time.  
Control Scheme  
The ACT6357 and ACT6358 use a minimum off-  
time, current-mode control scheme to achieve ex-  
cellent performance under high duty-cycle operating  
conditions. This control scheme initiates a switching  
cycle only when needed to maintain output voltage  
regulation, resulting in very high efficiency opera-  
tion.  
Over Voltage Protection  
Both the ACT6357 and ACT6358 include internal  
over-voltage protection circuitry that monitors the  
OV pin voltage. Over-voltage protection is critical  
when one of the LEDs in the LED string fails as an  
open circuit. When this happens the feedback volt-  
age drops to zero, and the control switches at maxi-  
mum on time causing the output voltage to keep  
rising until it exceeds the maximum voltage rating of  
the power MOSFET. The ACT6357 and ACT6358's  
over-voltage protection detects this condition and  
switching ceases if the voltage at the OV pin  
reaches 1.21V.  
During each switching cycle, the N-channel power  
MOSFET turns on, increasing the inductor current.  
The switching cycle terminates when either the in-  
ductor current reaches the current limit (500mA for  
the ACT6357, 1A for the ACT6358) or when the  
cycle lasts longer than the maximum on-time of  
4µs. Once the MOSFET turns off, it remains off for  
at least the minimum off-time of 320ns, then an-  
other switching begins when the error comparator  
detects that the output is falling out of regulation  
again.  
To set the maximum output voltage, connect a re-  
sistor divider from the output node to G, with center  
tap at OV, and select the two resistors with the fol-  
lowing equation:  
Soft-Start  
V  
OV  
The ACT6357 and ACT6358 include a programma-  
ble soft-start function, which can be used to opti-  
mize an application between start-up time and  
start-up inrush current. Soft start is achieved by  
connecting a capacitor CSS between the SS pin and  
G. The soft start duration can be calculated from  
the following equation:  
ROV2 = ROV1  
×
1  
1.21V  
where VOV is the over voltage detection threshold,  
OV1 is the resistor between OV and G, and ROV2 is  
the resistor from the output to the OV pin. As a first  
estimate, the OV threshold can often be set to 4V  
times the number of LEDs in the string.  
R
5μF  
CSS = tSS  
×
s