欢迎访问ic37.com |
会员登录 免费注册
发布采购

ACT5830_11 参数 Datasheet PDF下载

ACT5830_11图片预览
型号: ACT5830_11
PDF下载: 下载PDF文件 查看货源
内容描述: 十二通道PMU的手机 [Twelve Channel PMU for Mobile Phones]
分类和应用: 手机
文件页数/大小: 41 页 / 768 K
品牌: ACTIVE-SEMI [ ACTIVE-SEMI, INC ]
 浏览型号ACT5830_11的Datasheet PDF文件第33页浏览型号ACT5830_11的Datasheet PDF文件第34页浏览型号ACT5830_11的Datasheet PDF文件第35页浏览型号ACT5830_11的Datasheet PDF文件第36页浏览型号ACT5830_11的Datasheet PDF文件第37页浏览型号ACT5830_11的Datasheet PDF文件第38页浏览型号ACT5830_11的Datasheet PDF文件第39页浏览型号ACT5830_11的Datasheet PDF文件第41页  
®
ACT5830  
Rev 2, 20-Jan-11  
SINGLE-CELL Li+ BATTERY CHARGER (CHGR)  
FUNCTIONAL DESCRIPTIONS CONT’D  
state and charging can resume as defined by  
Figure 4.  
either:  
1) Pull nENCHG high, or Setting SUSCHG = [1].  
NO BAT State  
If the battery is reconnected while operating in the  
NO BAT state, the state machine resets the charge  
timers and jumps to the PRECONDITION state.  
The ACT5830 charger has been designed so that it  
will provide system power when there is no battery  
present. If the battery is not present at any time  
while a valid input voltage (>4V) is applied to  
CHG_IN, the ACT5830 will enable the charger and  
regulate the output at the voltage programmed by  
Reverse Battery  
The ACT5830 includes internal circuitry that  
eliminates the need for series blocking diodes,  
reducing solution size and cost as well as dropout  
voltage relative to conventional battery chargers.  
When the input supply is removed, when VIN goes  
below the ACT5830's under voltage-lockout (UVLO)  
voltage, or when VIN drops below VBAT, the  
ACT5830 automatically goes into SUSPEND mode  
and reconfigures its power switch to minimize  
current drain from the battery.  
CHGR/VSET[ ], simulating  
a
battery-present  
condition. The output current of the charger in this  
state is default to 1000mA to ensure full operation  
of the phone. When operating in this state, the  
charge timers are disabled but the thermal  
regulation loop is active. It is important for the  
application designer to consider both the power  
available from the charger as well as the thermal  
design in order to ensure proper system operation  
in this state. The user can prevent this operation by  
Figure 4:  
Charger State Diagram  
ANY STATE  
ANY STATE  
VBATID > 2.5V AND  
VCHG_IN < VBAT OR  
VCHG_IN > UVLO AND  
CHGR/SUSCHG[ ] = [0]  
VCHG_IN < UVLO OR  
CHGR/SUSCHG[ ] = [1]  
LDO-MODE  
SUSPEND  
BATTERY PRESENT AND  
VCHG_IN > VBAT AND  
VCHG_IN > UVLO AND  
CHGR/SUSCHG[ ] = [0]  
T > TIMOSET[ ] AND  
VBAT < 2.9V  
TIMEOUT-FAULT  
PRECONDITION  
VBAT > 2.9V  
Charge Timers  
Cleared  
FAST-CHARGE  
VBAT = VSET[ ]  
T > TIMOSET[ ]  
TOP-OFF  
Charge Timers  
not Cleared or  
IBAT > ISET[ ]/10  
IBAT < ISET[ ]/10  
or T > TIMOSET[ ]  
DELAY  
T > 32ms  
SLEEP  
VBAT < VSET[ ] – 200mV  
Innovative PowerTM  
- 40 -  
www.active-semi.com  
ActivePMUTM is a trademark of Active-Semi.  
I2CTM is a trademark of NXP.  
Copyright © 2010 Active-Semi, Inc.  
 复制成功!