ACT4910QW  
Rev 1.0, 15-Sept-2017  
CMI OPTIONS  
This section provides the basic default configuration settings for each available ACT4910 CMI option. Refer to each  
option’s application note for the comprehensive list of default settings  
CMI 121: ACT4910QW121  
CMI 121 is designed for standard 12V applications. CMI 121 default settings are appropriate for most typical applications.  
It provides the fastest buck switching frequency for the smallest solution sizes. Table 10 shows the default register  
settings.  
Table 10: CMI 121 Default Register Settings  
Function  
Value  
PLI & VOUT OK  
32ms  
Register  
0x19h  
Register Settings  
PLI_FUNC_SEL[1:0] = 11  
HMON_TSET[3:0] = 0100  
HMON_THR[3:0] = 0101  
EN_OV_REF[2:0] = 010  
EN_STARTDELAY = 0  
EN_LATCH_SPLMNT = 1  
BST_CLIM[1:0] = 10  
PLI Pin Function  
Health Monitor Time  
Health Monitor Threshold  
Enable Overvoltage Reference  
Startup Delay  
0x1Fh  
0x20h  
0x20h  
0x20h  
0x21h  
0x21h  
0x21h  
0x26h  
0x28h  
96%  
0.92V  
0ms  
Latch Supplement Mode  
Boost Current Limit  
Yes  
950mA  
28V  
Boost Voltage  
BST_VSET[4:0] = 10111  
BK_CLIM[1:0] = 11  
Buck Peak Current Limit  
Buck Switching Frequency  
9A  
1130kHz  
BK_FREQ[2:0] = 111  
I2C Address  
The CMI 121 7-bit I2C address is 0x5Ah. This results in 0xB4h for a write address and 0xB5h for a read address.  
Device ID  
The CMI 121 Device ID (register 0x3Bh) = 0x02h. This can be used to distinguish between different CMI versions.  
Autonomous ADC Supervisory Function  
The autonomous ADC supervisory function is disabled by default. All undervoltage register value are set to 0x00h and  
all overvoltage register values are set to 0xFFh.  