ACT4910QW  
Rev 1.0, 15-Sept-2017  
startup delay time, and current limit thresholds. Any  
changes to these registers are lost when power is  
recycled. The default values can be modified at the  
factory to optimize IC functionality for specific  
applications. Please consult sales@active-semi.com for  
custom options and minimum order quantities.  
The NORMAL state is the normal operating state after  
startup with no faults. The eFuse is fully on, VOUT =  
VIN, and the IC provides full operating current. Note that  
the IC charges the storage capacitors to their  
programmed value at the beginning of NORMAL state.  
HEALTH CHECK State  
When modifying only certain bits within a register, take  
care to not inadvertently change other bits.  
Inadvertently changing register contents can lead to  
unexpected device behavior.  
The HEALTH CHECK state can be considered a sub-  
state of NORMAL. The IC operates identical to the  
NORMAL state with the addition of activating the  
circuitry that check the storage capacitor health. The IC  
automatically enters HEALTH STATE every four  
minutes. The user may also manually enter this state by  
writing a 1 into the FORCE_HLTHCHK bit which is bit 1  
in register 0x0Ah. This bit automatically resets to 0 after  
the health check routine completes. The IC  
automatically exits HEALTH CHECK and enters  
SUPPLEMENT state in a fault condition.  
State Machine  
ACT4910 contains an internal state machine with seven  
internal states: UV/POR, SOFT-START, NORMAL,  
HEALTH CHECK, SUPPLEMENT, SHUTDOWN1, and  
SHUTDOWN2.  
UV/POR State  
SUPPLEMENT State  
The IC enters the UV/POR state on power up. It also  
enters UV/POR from SUPPLEMENT state in the  
following conditions:  
The IC enters SUPPLEMENT state when it detects a  
fault condition. It opens the eFuse to bi-directionally  
disconnect the input from the output. It automatically  
turn on the buck converter to power the output from the  
storage capacitors. The following five conditions move  
the IC into SUPPLEMENT state.  
1. When the input voltage drops below the EN_UV  
threshold.  
2. When the storage capacitor voltage drops  
below 3.6V.  
1. EN voltage below UV threshold  
2. EN voltage above the OV threshold  
3. Input voltage above the OV threshold  
4. eFuse current above the OC threshold  
5. VIN – VOUT > 560mV  
3. When the buck converter output voltage goes  
OV or UV.  
The user may force the IC into UV/POR by writing a 1  
into the FORCE_PWROFF bit, register 0x0Ah, bit 0.  
When entering UV/POR from power up, all registers  
reset to their default state. The registers retain their  
existing values when the IC enters from SUPPLEMENT  
state or from SHUTDOWN2 EFUSE. The IC transitions  
to the SOFT-START state when EN pin is above 0.64V  
and the input voltage is above UVLO.  
SHUTDOWN1 State  
SHUTDOWN1 protects against over temperature  
(145 °C), internal LDO failure, or boot capacitor failure.  
The eFuse remains on and continues to provide power  
to the output, but the boost converter is disabled. The  
ADC remains on and I2C functionality is still operational.  
The IC transitions to SHUTDOWN2 state if the die  
temperature increases to 155°C. If transitions back to  
the NORMAL state if the fault conditions go away.  
SOFTSTART State  
In the SOFTSTART state, the IC slowly turns on the  
eFuse to minimize inrush currents. The output voltage  
dV/dt ramp rate is controlled by the SS pin. The SS pin  
directly controls the maximum output voltage dV/dt  
while the ILIM pin indirectly controls it by limiting the  
current into the output capacitance. The IC stays in the  
SOFTSTART state until VIN-VOUT < 200mV and a  
10ms timer times out. Note that the output voltage may  
be fully charged up to VIN even though the IC in still in  
the SOFTSTART state. The storage caps charge up to  
the output voltage in this state.  
NORMAL State  
Innovative PowerTM  
ActiveSwitcherTM is a trademark of Active-Semi  
www.active-semi.com  
Copyright © 2017 Active-Semi, Inc.  
15  