ACT4524  
Rev 1.1, 22-Feb-16  
FUNCTIONAL BLOCK DIAGRAM  
HSB  
VIN  
PWM  
Controller  
UVLO  
70m  
CLK  
SW  
Driver  
MODE  
4.7Ω  
Current Sense  
and Control  
OVP  
CSN2  
CSP  
CSN1  
GND  
FUNCTIONAL DESCRIPTION  
converter goes into hiccup mode by disabling the  
converter and restarts in 4 seconds and restarts.  
Output Current Sensing and Regulation  
The conventional cycle-by-cycle peak current mode  
is implemented with high-side FET current sense.  
Cord Compensation  
Sense resistors are connected to the channel 1 and  
In some applications, the output voltage is  
increased with output current to compensate the  
potential voltage drop across output cable. The  
compensation is based on the high side feedback  
resistance.  
channel  
2 outputs, respectively. The sensed  
differential voltage is compared with interval  
reference to regulate current. CC loop and CV loop  
are in parallel. The current loop response is allowed  
to have slower response compared to voltage loop.  
However, during current transient response, the  
inductor current overshoot/undershoot should be  
controlled within +/-25% to avoid inductor  
saturation.  
For ACT4524, the compensation voltage can be  
derived as:  
ΔVout = RCS* IO*K  
Where RCS is the VOUT1 current resistance, IO is the  
output current, and K is the cord compensation  
factor. This voltage difference could be added on  
the reference or turning the (VCSP-VCSN) voltage into  
a sink current at FB pin to pull Vout higher than  
programmed voltage.  
Input Over Voltage Protection  
The converter is disabled if the input voltage is  
above 42V (+/-2V). Device resumes operation  
automatically 40ms after OVP is cleared.  
The cord compensation loop should be very slow to  
avoid potential disturbance to the voltage loop. The  
voltage loop should be sufficiently stable on various  
cord compensation setting.  
Output Over Voltage Protection  
Device stops switching when output over-voltage is  
sensed, and resumes operation automatically when  
output voltage drops to OVP- hysteresis.  
Thermal Shutdown  
If the TJ increases beyond 160°C, ACT4524 goes  
into HZ mode and the timer is preserved until TJ  
drops by 30°C.  
Output Under-Voltage Protection /  
Hiccup Mode  
There is  
a
under voltage protection (UVP)  
threshold. If the UVP threshold is hit for 10us, an  
over current or short circuit is assumed, and the  
Innovative PowerTM  
- 5 -  