ACT4524
Rev 1.1, 22-Feb-16
TYPICAL PERFORMANCE CHARACTERISTICS
(Schematic as show in Figure 1, Ta = 25°C, unless otherwise specified)
Output Short Test
Power Off from CC load
VIN = 12V
VOUT = 5.1V
IOUT = 3.6A
VIN = 12V
Vout=5.1V
IOUT = 3.4A
CH1
CH1
CH2
CH2
CH3
CH3
CH4
CH1: VIN, 5V/div
CH2: VOUT, 2V/div
CH3: IL, 5A/div
CH4: SW, 10V/div
TIME: 1ms//div
CH1: VOUT, 2V/div
CH2: IL, 5A/div
CH3: SW, 10V/div
TIME: 2s//div
SW vs. Output Voltage Ripples
Output Short Recovery
VIN = 12V
IOUT1 = 0A
Iout2 = 1.0A
VIN = 12V
VOUT = 5.1V
IOUT = 3.6A
CH1
CH1
CH2
CH2
CH3
CH3
CH1: SW, 10V/div
CH2: VOUT1 Ripple, 50mV/div
CH3: VOUT2 Ripple, 50mV/div
TIME: 4µs/div
CH1: VOUT, 2V/div
CH2: IL, 5A/div
CH3: SW, 10V/div
TIME: 2s//div
SW vs. Output Voltage Ripples
SW vs. Output Voltage Ripples
VIN = 12V
IOUT1 = 2.4A
Iout2= 0A
VIN = 12V
IOUT1 = 2.4A
Iout2= 1.0A
CH1
CH2
CH1
CH2
CH3
CH3
CH1: SW, 10V/div
CH1: SW, 10V/div
CH2: VOUT1 Ripple, 50mV/div
CH3: VOUT2 Ripple, 50mV/div
TIME: 4µs/div
CH2: VOUT1 Ripple, 50mV/div
CH3: VOUT2 Ripple, 50mV/div
TIME: 4µs/div
Innovative PowerTM
- 14 -
www.active-semi.com
Copyright © 2015 Active-Semi, Inc.