欢迎访问ic37.com |
会员登录 免费注册
发布采购

ACT2803_16 参数 Datasheet PDF下载

ACT2803_16图片预览
型号: ACT2803_16
PDF下载: 下载PDF文件 查看货源
内容描述: [5V/2.4A Dual Cell Battery Power Manager]
分类和应用: 电池
文件页数/大小: 22 页 / 523 K
品牌: ACTIVE-SEMI [ ACTIVE-SEMI, INC ]
 浏览型号ACT2803_16的Datasheet PDF文件第9页浏览型号ACT2803_16的Datasheet PDF文件第10页浏览型号ACT2803_16的Datasheet PDF文件第11页浏览型号ACT2803_16的Datasheet PDF文件第12页浏览型号ACT2803_16的Datasheet PDF文件第14页浏览型号ACT2803_16的Datasheet PDF文件第15页浏览型号ACT2803_16的Datasheet PDF文件第16页浏览型号ACT2803_16的Datasheet PDF文件第17页  
ACT2803  
Rev 1, May-12-2016  
APPLICATIONS INFORMATION  
LEDLS3, LEDLS4 to APNG respectively, as shows  
in Figure3.  
Fast Charge Current Control  
The block diagram in Figure 2 shows how battery  
current is sensed for charge current control.  
RHYST  
RIMC  
RLS2 RLS3  
RLS1  
RLS4  
ACT2803  
Figure 2: Battery current monitoring  
A small percentage of charge current is sensed and  
sinked into a resistor connected at pin ICST. In  
charge mode, this would allow user to set fast  
charge current based on the following equation.  
Figure 3: LED threshold setting  
The following equation shows how the external  
resistor shifts the LED thresholds. The range of  
LED1LED4 indicator threshold shift from 5.5V‐  
8.8V.  
1000  
Ic(A)   
(1)  
5* RCS (m)* RICST (k)  
108k  
RLSx (k)  
For example, IC=1A with RCS=25mΩ and  
VLEDX (V ) 5.5V   
(3)  
R
ICST=8kΩ.  
Recommended RICST is shown in following table:  
VLED Example is given by the below table:  
RICST  
IC (A)  
Units  
RLSx  
(kΩ)  
VLEDx  
(V)  
RLSx  
(kΩ)  
VLEDx  
(V)  
R
CS=25mΩ  
RCS=50mΩ  
5
0.8  
0.9  
1.0  
1.1  
1.2  
1.3  
1.4  
1.5  
10  
k  
kΩ  
kΩ  
kΩ  
kΩ  
kΩ  
kΩ  
kΩ  
72  
7
40  
43.2  
47  
8.2  
8
8.89  
8
4.44  
4
90  
6.7  
6.5  
6.4  
6.3  
6.1  
5.9  
108  
120  
135  
180  
270  
7.798  
7.7  
7.27  
6.67  
6.15  
5.71  
5.33  
3.64  
3.33  
3.08  
2.86  
2.67  
49.1  
57  
7.395  
7.3  
60  
67.5  
7.1  
During discharge mode, inputs of battery current  
sense amp are flipped to sense discharge current,  
and voltage level at pin ICST can be used (by the  
system) to monitor the magnitude of discharge  
current based on the following equation.  
LED Hysteresis Window Setting  
The adjustable LED voltage thresholds are set for  
HZ mode. In charge mode, the measured battery  
voltage is higher than in HZ mode, while in  
discharge mode, the measured battery voltage is  
lower. To have relatively better “fuel gauge” for  
battery, a programmable hysteresis window will  
help. When the battery voltage goes up (in charge  
mode), the thresholds become higher, when the  
battery voltage goes down, lower thresholds are  
applied.  
IDISCHARGE RICST  
VICST  
(2)  
20k  
For example: VICST=0.4V with I_DISCHARGE=1A,  
and RICST=8kΩ.  
LED Threshold Setting  
ACT2803 provide HYST pin to set hysteresis  
window for each indication level as shows in Figure  
3 .  
LED1, LED2, LED3 and LED4 thresholds are  
adjustable with external resistors RLS1, RLS2, RLS3  
,
and RLS4 connected from LEDLS1, LEDLS2,  
Innovative PowerTM  
- 13 -  
www.active-semi.com  
Copyright © 2016 Active-Semi, Inc.  
 复制成功!