Integrator Series FPGAs: 1200XL and 3200DX Families  
3.3V Operating Conditions  
Recommended Operating Conditions  
Parameter  
Commercial  
Units  
1
Absolute Maximum Ratings  
1
Temperature Range  
0 to +70  
±5  
°C  
Free Air Temperature Range  
Power Supply Tolerance  
%V  
Note:  
Symbol  
Parameter  
Limits  
Units  
1. Ambient temperature (TA) is used for commercial.  
V
V
V
DC Supply Voltage  
Input Voltage  
–0.5 to +7.0  
V
V
CC  
2
I
–0.5 to V +0.5  
CC  
Output Voltage  
–0.5 to V +0.5  
CC  
V
O
T
Storage Temperature  
–65 to +150  
°C  
STG  
Notes:  
1. Stresses beyond those listed under “Absolute Maximum  
Ratings” may cause permanent damage to the device.  
Exposure to absolute maximum rated conditions for extended  
periods may affect device reliability. Device should not be  
operated outside the Recommended Operating Conditions.  
2. Device inputs are normally high impedance and draw  
extremely low current. However, when input voltage is greater  
than VCC + 0.5V or less than GND – 0.5V, the internal protection  
diodes will forward bias and can draw excessive current.  
Electrical Specifications  
Commercial  
Parameter  
Units  
Min.  
Max.  
(I = –4 mA)  
2.15  
2.4  
V
V
OH  
1
V
OH  
(I = –3.2 mA)  
OH  
1
V
V
V
(I = 6 mA)  
0.4  
0.8  
V
OL  
OL  
–0.3  
2.0  
V
IL  
V
+ 0.3  
V
IH  
CC  
2
Input Transition Time t , t  
R
500  
10  
ns  
pF  
mA  
F
2, 3  
C
I/O Capacitance  
IO  
4
Standby Current, I  
(typical = 0.3 mA)  
0.75  
CC  
I
Dynamic V Supply Current  
CC  
See the “Power Dissipation” section on page 14.  
Can be converted from IBIS model on the web.  
CC(D)  
4
IV Curve  
Notes:  
1. Only one output tested at a time. VCC = min.  
2. Includes worst-case 84-pin PLCC package capacitance. VOUT = 0 V, f = 1 MHz.  
3. Typical standby current = 0.3 mA. All outputs unloaded. All inputs = VCC or GND.  
4. The IBIS model can be found at www.actel.com/support/support/support_ibis.html.  
Discontinued – v3.0  
13