Absolute Maximum Ratings1  
Recommended Operating Conditions  
Free air temperature range  
Parameter  
Commercial  
Military  
Units  
Symbol  
Parameter  
Limits  
Units  
Temperature  
Range1  
0 to +70  
–55 to +125  
°C  
VCC  
VI  
DC Supply Voltage2, 3, 4  
Input Voltage  
–0.5 to +7.0  
–0.5 to VCC +0.5  
–0.5 to VCC +0.5  
±20  
V
V
Power Supply  
Tolerance2  
±5  
±10  
%VCC  
VO  
IIO  
Output Voltage  
V
Notes:  
I/O Source Sink  
Current5  
mA  
1. Ambient temperature (TA) is used for commercial and  
industrial; case temperature (TC) is used for military.  
2. All power supplies must be in the recommended operating range.  
For more information, refer to the Power-Up Design Considerations  
application note at http://www.actel.com/appnotes.  
TSTG  
Storage Temperature  
–65 to +150  
°C  
Notes:  
1. Stresses beyond those listed under “Absolute Maximum Ratings”  
may cause permanent damage to the device. Exposure to  
absolute maximum rated conditions for extended periods may  
affect device reliability. Devices should not be operated outside  
the recommended operating conditions.  
2. VPP = VCC , except during device programming.  
3. VSV = VCC , except during device programming.  
4.  
5. Device inputs are normally high impedance and draw extremely  
low current. However, when input voltage is greater than VCC  
VKS = GND , except during device programming.  
+
0.5V or less than GND – 0.5V, the internal protection diode will be  
forward biased and can draw excessive current.  
Electrical Specifications  
Commercial  
Military  
Max.  
Symbol Parameter  
Test Condition  
Min.  
Max.  
Min.  
Units  
1, 2  
VOH  
HIGH Level Output  
IOH = –4 mA (CMOS)  
3.7  
V
V
I
OH = –6 mA (CMOS)  
3.84  
1, 2  
VOL  
VIH  
VIL  
LOW Level Output  
HIGH Level Input  
LOW Level Input  
Input Leakage  
IOL = +6 mA (CMOS)  
TTL Inputs  
0.33  
VCC + 0.3  
0.8  
0.4  
VCC + 0.3  
0.8  
V
2.0  
–0.3  
–10  
–10  
2.0  
–0.3  
–10  
–10  
V
TTL Inputs  
V
IIN  
VI = VCC or GND  
VO = VCC or GND  
+10  
+10  
µA  
µA  
pF  
IOZ  
3-state Output Leakage  
I/O Capacitance3, 4  
+10  
+10  
CIO  
ICC(S)  
10  
10  
Standby VCC Supply Current VI = VCC or GND, IO = 0 mA  
ACT 1  
3
2
20  
20  
mA  
mA  
ACT 2/3/1200XL/3200DX  
ICC(D)  
Dynamic VCC Supply Current  
See the “Power Dissipation” section on page 11.  
Notes:  
1. Actel devices can drive and receive either CMOS or TTL signal levels. No assignment of I/Os as TTL or CMOS is required.  
2. Tested one output at a time, VCC = min.  
3. Not tested; for information only.  
4. VOUT = 0V, f = 1 MHz  
10