Stability Characteristics
Test item
Mechanical shock
Condition of test
(a) Drops: 3 times on concrete floor
1
2
3
(b) Height: 1.0 m
(a) Frequency of vibration: 10~55Hz
(c) Directions: X,Y and Z
(b) Amplitude: 1.5 mm
(d) Duration: 2 hours
Vibration resistance
Moisture resistance
(a) Condition: 40°C, 90~95% R.H.
(b) Duration: 96 hours
(c) Wait 4 hours before measurement
(a) +70°C for 16 hours
(c) -25°C for 2 hours
(b) +55°C for 24 hours, 90~95% R.H.
(d) +40°C for 24 hours, 90~95% R.H.
4
Climatic sequence
(e) Wait 4 hours before measurement
(a) Temperature: 70°C
(c) Wait 4 hours before measurement
(b) Duration: 250 hours
5
6
High temperature exposure
Thermal impact
(a) +70°C for 30 minutes -25°C for 30 minutes repeated 3 times
(b) Wait 4 hours before measurement
Requirements: The SAW filer shall remain within the electrical specifications after tests.
Remarks
SAW devices should not be used in any type of fluid such as water, oil, organic solvent, etc.
Be certain not to apply voltage exceeding the rated voltage of components.
Do not operate outside the recommended operating temperature range of components.
Sudden change of temperature shall be avoided, deterioration of the characteristics can occur.
Be careful of soldering temperature and duration of components when soldering.
Do not place soldering iron on the body of components.
Be careful not to subject the terminals or leads of components to excessive force.
SAW devices are electrostatic sensitive. Please avoid static voltage during operation and storage.
Ultrasonic cleaning shall be avoided. Ultrasonic vibration may cause destruction of components.
Test Circuit
Recommended Land Pattern