5. Performance
5-1. Maximum Ratings
Rating
Value
Unit
Input Power Level
DC Voltage
P
10
dBm
V
VDC
TA
5
Operable Temperature Range
Storage Temperature Range
-20 to +75
-40 to +85
℃
Tstg
℃
5-2. Electronic Characteristics
Characteristic
Minimum
Typical
Maximum
Unit
Center Frequency
Insertion Loss
fC
--
1855.0
--
MHz
IL
1840 …. 1870 MHz
1840 …. 1870 MHz
--
--
3.0
1.4
4.5
2.0
dB
VSWR
Absolute Attenuation
±
1440 …. 1470 MHz
1750 …. 1780 MHz
1930 …. 1960 MHz
2240 …. 2270 MHz
20
28
25
27
27
40
35
37
--
--
--
--
dB
dB
dB
dB
Amplitude Ripple (p-p)
” ±
1840 …. 1870 MHz
--
0.8
50
1.5
dB
Input / Output Impedance (Nominal)
Ω
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
C ACT 2003. All Rights Reserved.
○
NOTE:
1. The frequency fC is defined as the midpoint between the 3dB frequencies.
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50© test system with VSWRd1.2:1.
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.
4. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence
without notice.
5. All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
6. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
.