欢迎访问ic37.com |
会员登录 免费注册
发布采购

ACTF9011 参数 Datasheet PDF下载

ACTF9011图片预览
型号: ACTF9011
PDF下载: 下载PDF文件 查看货源
内容描述: [RF filter]
分类和应用:
文件页数/大小: 3 页 / 66 K
品牌: ACT [ ADVANCED CRYSTAL TECHNOLOGY ]
 浏览型号ACTF9011的Datasheet PDF文件第1页浏览型号ACTF9011的Datasheet PDF文件第2页  
Tel : +44 118 979 1238  
Fax : +44 118 979 1283  
Email: info@actcrystals.com  
5-2. Electronic Characteristics  
Characteristic  
Nominal Centre Frequency  
Minimum  
Typical  
915.000  
26  
Maximum  
Unit  
MHz  
MHz  
fC  
--  
--  
--  
--  
Usable Pass Bandwidth  
BW  
Insertion Loss  
IL  
--  
--  
3.5  
1.5  
5.0  
--  
dB  
dB  
902.00 …. 928.00 MHz  
Inband Ripple  
Δα  
α
902.00 …. 928.00 MHz  
Absolute Attenuation  
DC …. 800.00 MHz  
25  
30  
30  
20  
27  
35  
40  
25  
--  
--  
--  
--  
dB  
dB  
dB  
dB  
800.00 …. 880.00 MHz  
950.00 …. 1080.0 MHz  
1080.0 …. 2000.0 MHz  
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!  
1. The frequency fC is defined as the midpoint between the 3dB frequencies.  
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is  
connected to a 50 Ω test system with VSWR 1.2:1. The test fixture L and C are adjusted for minimum insertion  
loss at the filter centre frequency, fC. Note that insertion loss, bandwidth, and passband shape are dependent on  
the impedance matching component values and quality.  
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.  
4. The specifications of this device are based on the test circuit shown above and subject to change or  
obsolescence without notice.  
5. All equipment designs utilizing this product must be approved by the appropriate government agency prior to  
manufacture or sale.  
6. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,  
processes and circuits implemented within components or assemblies.  
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.  
ISO9001: 2000 Registered - Registration number 6830/2  
For quotations or further information please contact us at:  
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK  