5-2. Electronic Characteristics ( TA = 25°C )  
Characteristic  
Minimum  
Typical  
866.000  
19  
Maximum  
Unit  
MHz  
MHz  
MHz  
Centre Frequency  
3dB Bandwidth  
Usable Passband  
Insertion Loss  
fC  
BW3  
BW  
IL  
±4.0  
within fC ± 4.0 MHz  
3.0  
1.2  
4.5  
2.0  
dB  
dB  
Amplitude Ripple (p-p)  
within fC ± 4.0 MHz  
Δα  
α
Absolute Attenuation  
fC 400.0  
~
~
fC 30.0 MHz  
fC 400.0 MHz  
42  
40  
52  
48  
dB  
dB  
fC 50.0  
Terminating Impedance  
50// 10nH  
LCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!  
NOTE:  
1. The frequency fC is defined as the midpoint between the 3dB frequencies.  
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is  
connected to a 50test system with VSWR 1.2:1. The test fixture L and C are adjusted for minimum insertion loss  
at the filter centre frequency, fC. Note that insertion loss, bandwidth, and passband shape are dependent on the  
impedance matching component values and quality.  
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.  
4. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence  
without notice.  
5. All equipment designs utilizing this product must be approved by the appropriate government agency prior to  
manufacture or sale.  
6. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,  
processes and circuits implemented within components or assemblies.  
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.  
ISO9001: 2000 Registered  
For quotations or further information please contact us at:  
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK  
http://www.actcrystals.com  
Issue : 2 C1u  
Date : SEPT 06