5. Performance
5-1. Maximum Ratings
Rating
Value
10
Unit
dBm
V
Input Power Level
DC Voltage
Pin
VDC
Tstg
TA
6
Storage Temperature Range
Operating Temperature Range
-45 to +120
-45 to +120
℃
℃
5-2. Electronic Characteristics
Characteristic
Nominal Center Frequency
Minimum
Typical
Maximum
Unit
fC
433.920
MHz
Insertion Loss
IL
(at minimum loss point)
2.8
1.0
3.5
dB
3dB Bandwidth (from fC)
BW3
0.9
MHz
Relative attenuation (relative to IL)
±
rel
fC± 21.4 MHz
fC± 10.7 MHz
fC± 1.0 MHz
36
30
10
44
38
dB
dB
dB
Ultimate Rejection
50
60
dB
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
C ACT. All Rights Reserved.
○
1. The frequency fC is defined as the midpoint between the 3dB frequencies.
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50© test system with VSWRd1.2:1.
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.
4. The specifications of this device are based on the test circuit shown above and subject to change or obsolescence
without notice.
5. All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
6. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
1 / 4-2-2013