5-2.Electronic Characteristics  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Centre Frequency  
(Centre frequency between 3dB points)  
fC  
315.000  
MHz  
Insertion Loss  
IL  
BW3  
--  
3.5  
±300  
50  
5.0  
±500  
--  
dB  
3dB Pass band  
kHz  
at fC -21.4MHz (Image)  
40  
15  
--  
Rejection  
dB  
at fC -10.7MHz (LO)  
Ultimate  
30  
--  
60  
--  
Turnover Temperature  
Turnover Frequency  
Frequency Temperature Coefficient  
TO  
25  
55  
°C  
Temperature  
fO  
fc  
0.03  
10  
MHz  
ppm/°C2  
FTC  
|fA|  
Frequency Aging Absolute Value during the First Year  
ppm/yr  
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling!  
i
1. The frequency fC is defined as the midpoint between the 3dB frequencies.  
2. Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is  
connected to a 50 Ω test system with VSWR1.2:1. The test fixture L and C are adjusted for minimum  
insertion loss at the filter centre frequency, fC. Note that insertion loss, bandwidth, and passband shape are  
dependent on the impedance matching component values and quality.  
3. Unless noted otherwise, specifications apply over the entire specified operating temperature range.  
4. Frequency aging is the change in fC with time and is specified at +65°C or less. Aging may exceed the  
specification for prolonged temperatures above +65°C. Typically, aging is greatest the first year after  
manufacture, decreasing in subsequent years.  
5. Turnover temperature, T0, is the temperature of maximum (or turnover) frequency, f0. The nominal frequency  
at any case temperature, TC, may be calculated from: f = f0 [1 - FTC (T0 - TC)2].  
6. The specifications of this device are based on the test circuit shown above and subject to change or  
obsolescence without notice.  
7. All equipment designs utilizing this product must be approved by the appropriate government agency prior to  
manufacture or sale.  
8. Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,  
processes and circuits implemented within components or assemblies.  
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.  
ISO9001: 2000 Registered  
Issue : 1 C1  
Date : SEPT 04  
For quotations or further information please contact us at:  
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK  
http://www.actcrystals.com  
3 OF 3