Tel :
+44 118 979 1238
Fax : +44 118 979 1283
Email:info@actcrystals.com
Typical Frequency Response
Environmental Characteristic
Test item
Condition of test
(a) Drops: 3 times on concrete floor
Requirements
Mechanical
shock
1
2
3
(b) Height: 1.0m
Vibration
resistance
(a) Frequency of vibration: 10~55Hz (b) Amplitude: 1.5mm
(c) Directions: X,Y and Z
(d) Duration: 2 hours
(b) Duration: 96 hours
Moisture
resistance
(a) Condition: 40°C, 90~95% R.H.
(c) Wait 4 hours before measurement
The SAW filter
shall remain within
the electrical
(a) +70℃ for 16 hours
(b) +55℃ for 24 hours, 90~95% R.H.
(c) -25℃ for 2 hours
(d) +40℃ for 24 hours, 90~95% R.H.
(e) Wait 4 hours before measurement
Climatic
sequence
4
specifications
after tests.
High
Temperature
Exposure
(a) Temperature: 70°C
(b) Duration: 250 hours
(c) Wait 4 hours before measurement
5
6
(a) +70°C for 30 minutes ⇒ -25°C for 30 minutes repeated 3 times
(b) Wait 4 hours before measurement
Thermal impact
- 3 -
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com