Electrical Characteristics (@25°C)  
Characteristic  
Center Frequency  
Minimum  
Typical  
140.0  
9.3  
Maximum  
Unit  
MHz  
dB  
fC  
IL  
--  
--  
--  
Insertion Loss (@140.00MHz)  
11.0  
1dB Bandwidth  
20.4  
129.7  
150.4  
21.6  
129.3  
150.9  
24.4  
--  
130.8  
Lower 1dB Band edge  
Upper 1 dB Band edge  
3dB Bandwidth  
Lower 3dB Band edge  
Upper 3 dB Band edge  
35dB Bandwidth  
BW1  
BW3  
MHz  
MHz  
149.2  
--  
130.2  
149.8  
126.8  
Lower 35 dB Band edge  
Upper 35 dB Band edge  
BW35  
128.0  
152.4  
MHz  
dB  
153.2  
0.8  
Pass band ripple(over the 1 dB bandwidth)  
--  
0.5  
Relative Attenuation  
10-90MHz  
--  
--  
35  
40  
35  
35  
40  
35  
55  
53  
45  
39  
49  
58  
90-120MHz  
120-126.8MHz  
153.2-160MHz  
160-190MHz  
190-800MHz  
dB  
Input VSWR  
2.0  
1.8  
50  
2.5  
2.3  
Output VSWR  
Source/Load Impedance  
RoHS Compliant  
Electrostatic Sensitive Device  
Stability Characteristics  
Test item  
Condition of test  
(a) Drops: 3 times on concrete floor  
(b) Height: 1.0 m  
1
2
3
Mechanical shock  
Vibration resistance  
Moisture resistance  
(a) Frequency of vibration: 10~55Hz  
(c) Directions: X,Y and Z  
(b) Amplitude: 1.5 mm  
(d) Duration: 2 hours  
(a) Condition: 40°C, 90~95% R.H.  
(c) Wait 4 hours before measurement  
(b) Duration: 96 hours  
(a) +70°C for 16 hours  
(c) -25°C for 2 hours  
(b) +55°C for 24 hours, 90~95% R.H.  
(d) +40°C for 24 hours, 90~95% R.H.  
4
Climatic sequence  
(e) Wait 4 hours before measurement  
(a) Temperature: 70°C  
(c) Wait 4 hours before measurement  
(b) Duration: 250 hours  
5
6
High temperature exposure  
Thermal impact  
(a) +70°C for 30 minutes -25°C for 30 minutes repeated 3 times  
(b) Wait 4 hours before measurement  
Requirements: The SAW filter shall remain within the electrical specifications after tests.  
Iss1 C1u, Date 13-7-2011  
Page 5 of 6  
 复制成功!