Electrical Characteristics (@25°C)
Characteristic
Center Frequency
Minimum
Typical
140.0
9.3
Maximum
Unit
MHz
dB
fC
IL
--
--
--
Insertion Loss (@140.00MHz)
11.0
1dB Bandwidth
20.4
129.7
150.4
21.6
129.3
150.9
24.4
--
130.8
Lower 1dB Band edge
Upper 1 dB Band edge
3dB Bandwidth
Lower 3dB Band edge
Upper 3 dB Band edge
35dB Bandwidth
BW1
BW3
MHz
MHz
149.2
--
130.2
149.8
126.8
Lower 35 dB Band edge
Upper 35 dB Band edge
BW35
128.0
152.4
MHz
dB
153.2
0.8
Pass band ripple(over the 1 dB bandwidth)
--
0.5
Relative Attenuation
10-90MHz
--
--
35
40
35
35
40
35
55
53
45
39
49
58
90-120MHz
120-126.8MHz
153.2-160MHz
160-190MHz
190-800MHz
dB
Input VSWR
2.0
1.8
50
2.5
2.3
Output VSWR
Source/Load Impedance
Ω
RoHS Compliant
Electrostatic Sensitive Device
Stability Characteristics
Test item
Condition of test
(a) Drops: 3 times on concrete floor
(b) Height: 1.0 m
1
2
3
Mechanical shock
Vibration resistance
Moisture resistance
(a) Frequency of vibration: 10~55Hz
(c) Directions: X,Y and Z
(b) Amplitude: 1.5 mm
(d) Duration: 2 hours
(a) Condition: 40°C, 90~95% R.H.
(c) Wait 4 hours before measurement
(b) Duration: 96 hours
(a) +70°C for 16 hours
(c) -25°C for 2 hours
(b) +55°C for 24 hours, 90~95% R.H.
(d) +40°C for 24 hours, 90~95% R.H.
4
Climatic sequence
(e) Wait 4 hours before measurement
(a) Temperature: 70°C
(c) Wait 4 hours before measurement
(b) Duration: 250 hours
5
6
High temperature exposure
Thermal impact
(a) +70°C for 30 minutes -25°C for 30 minutes repeated 3 times
(b) Wait 4 hours before measurement
Requirements: The SAW filter shall remain within the electrical specifications after tests.
Iss1 C1u, Date 13-7-2011
Page 5 of 6