RELIABILITY
Specified Value
Item
Test Methods and Remarks
AL02, AL03 Type
AL04 Type
AL05 Type
16. Resistance to Solvent
17. Thermal shock
Please avoid the ultrasonic cleaning of this product.
∆L/L →Within 10% ∆L/L →Within 10% ∆L/L →Within 5%
Conditions for 1 cycle
Q →30min.
Q/Q →Within 30% Q →15min.
Step
Temperature(˚C)
Duration(min)
30
within 3
30
within 3
+0
1
2
-25
3
-3
Room temperature
+2
+85
-0
3
4
3
Room temperature
Number of cycles: 5 cycles
Recovery: At least 1 hr of recovery under the standard condition
after the removal from test chamber, followed by the measurement
within 2 hrs.
18. Damp Heat
∆L/L →Within 10% ∆L/L →Within 10% ∆L/L →Within 5%
Q →30min. Q/Q →Within 30% Q →15min.
- Temperature: 40 2˚C
- Duration: 1000hrs
- Humidity: 90 to 95% RH
- Recovery: At least 1 hr of recovery under the standard condition
after the removal from test chamber, followed by the measurement
within 2 hrs.
19. Loading under Tensile
Damp Heat
∆L/L →Within 10% ∆L/L →Within 10% ∆L/L →Within 5%
Q →30min. Q/Q →Within 30% Q →15min.
- Temperature: 40 2˚C
- Duration: 1000hrs
- Humidity: 90 to 95% RH
- Applied current: Rated current
- Recovery: At least 1 hr of recovery under the standard condition
after the removal from test chamber, followed by the measurement
within 2 hrs.
20. Loading at High
Temperature
∆L/L →Within 10% ∆L/L →Within 10% ∆L/L →Within 5%
Q →30min. Q/Q →Within 30% Q →15min.
- Temperature: 85 2˚C
- Applied current: Rated current
- Duration: 1000hrs
- Recovery: At least 1 hr of recovery under the standard condition
after the removal from test chamber, followed by the measurement
within 2 hrs.
21. Low Temperature
Life Test
∆L/L →Within 10% ∆L/L →Within 10% ∆L/L →Within 5%
Q →30min. Q/Q →Within 30% Q →15min.
- Temperature: -25 2˚C
- Applied current: Rated current
- Duration: 1000hrs
- Recovery: At least 1 hr of recovery under the standard condition
after the removal from test chamber, followed by the measurement
within 2 hrs.
Note on standard condition: “standard condition” referred to herein is defined as follows.
5 to 35˚C of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure.
When there are questions concerning measurement results: In order to provide correlation data, the test shall be conducted under condition of 20 2˚C of temperatue,
45 to 85% relative humidity and 86 to 106kPa of air pressure Unless otherwise specified, all the tests are conducted under the “standard condition”
■PACKING
Inner Box
Size(m/m)
Out Box
Taping
Lead
Style
Type
Item
Size(m/m)
(W × H ×L)
Weight
(100µH)
Quantity
Quantity
(W × H ×L)
AL02
ALC02
ALN02
AL03
8.5kg
TA
TB
TR
26m/m
52m/m
52m/m
50×65×252
2,000
285×260×455
54,000
9.5kg
11kg
AL02
70×65×265
2,500
285×250×455
6kg
ALC02,
ALN02
45,000
70×85×265
70×110×355
70×110×355
2,500
2,500
2,000
285×305×455
330×260×485
7kg
6kg
AL03
AL04
AL05
AL02
ALC02
AL03
AL04
30,000
24,000
10kg
5,000
50,000
14kg
280×280
(A×A)
460×320×600
4,000
2,500
40,000
25,000
14kg
16kg
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before your order and/or use.
56