PRODUCT DATASHEET
SynJet LED Cooler R87-46
SynJet cooling technology provides the most reliable thermal
management solution available. This LED cooler has been developed
by Nuventix for cooling downlight and spotlight modules and arrays.
Cools up to 38 W
4
Reliable 100K Hours Lifetime
Energy Efficient
5 Yr Warranty
Small Form Factor
Quiet Acoustics
®
Specifications
1
Thermal & Acoustic
SynJet Setting
Mid Performance
Standard Performance
Silent Performance
PWM at 100% duty cycle
Heatsink Only
Θs-a
Al
TDP (W)
ΔT = 30° / 40°C
36 / 48
33 / 43
29 / 39
38 / 51
12
SPL
(dBA)
25
22
19
27
N/A
Wire Connections
Red to +VDC
Black & Blue to Ground
Red to +VDC
Black only to Ground
Red to +VDC
Black & Purple to Ground
Red to +VDC
Black only to Ground
Blue to PWM Signal
N/A
N/A
0.84
0.92
1.03
0.79
2.41
Electrical
SynJet Setting
2
Voltage
(VDC)
+/- 10%
5
Current (mA)
Imin
20
Iavg
150
95
65
160
Mid
Standard
Silent
PWM at 100% duty cycle
Ipeak
300
190
130
320
Pavg
(mW)
750
475
325
800
Voltage
(VDC)
+/- 10%
12
Current (mA)
Imin
10
Iavg
67
50
40
82
6
Ipeak
134
100
80
164
Pavg
(mW)
800
600
480
980
Environmental
All Settings
Operating Temperature
Storage Temperature
Storage Altitude
Operating Relative Humidity
Weight
Reliability
Regulatory Compliance
Min
-40
-50
5
Max
70
75
15K
95
335
100K
Units
°C
°C
m
%
g
hrs
Conditions
Air temperature surrounding cooler
Air temperature surrounding cooler
Above sea level
Non-condensing
SynJet with Al heat sink
L10 @ 60°C
RoHS, UL, FCC Part 15 Class B, CE
Mechanical
-
SynJet Cooling Solution shown with Configurable heat sink
1
2
All values are typical at 25ºC unless otherwise stated.
The Level Select model should be used for discrete performance settings. Follow the instructions in the Product Design Guide for adjusting settings.
3
Thermal resistance values are given as reference only and are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom
middle of the heat sink to ambient air measured at the inlet to the SynJet, with a heat source at least 4.1cm
2
using the 60 W reference heat sink. Actual thermal
performance may vary by application and final product design should be tested to assure proper thermal performance.
4
Thermal Design Power is based on a 30ºC or 40ºC temperature rise of heat sink mounting surface above ambient temperature around cooler.
5
Sound Pressure Level is measured at 1 meter distance per ISO 7779.
6
The SynJet has a time varying current. The current waveform is sinusoidal and the average current (Iavg) is used to calculate the average power consumption
(Pavg) at nominal input voltage (VDC). See the Electrical section in the Product Design Guide for a detailed explanation.
4635 Boston Lane
Austin, TX 78735
Phone: 512-382-8100
www.nuventix.com