 浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第5页浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第6页浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第7页浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第8页浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第10页浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第11页浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第12页浏览型号AAT4626IHS-1-T1的Datasheet PDF文件第13页  
AAT4626  
USB Dual-Channel Power Switch  
from effecting the operation of the AAT4626. For  
example, if an AAT4626 is used in a circuit that oper-  
ates from a 5V power supply with poor step load  
response, it is possible that turning on the load  
switch could cause the input power supply to droop  
below the AAT4626's under-voltage lockout thresh-  
old. This drop in voltage would cause the AAT4626  
to turn off until the input power supply voltage levels  
recover. Since this cycle would be self-perpetuating,  
the entire circuit could be seen to be unstable. In the  
very rare case where capacitor cost is prohibitive  
and the input capacitor is omitted, the output load cir-  
cuit should be slew rate limited when turned on.  
as CMOS-compatible levels ranging from 2.5V to  
5V. The ENA or ENB function control voltage levels  
should not exceed the input supply level applied to  
the IN pin.  
Fault Flag Output  
The AAT4626 features an active low fault flag  
(FLGA and FLGB) output for each A and B output  
channel. The fault flags are provided to alert the  
system if the over-current or over-temperature cir-  
cuits become active, or if the load switch is not  
receiving a sufficient voltage level to properly oper-  
ate. If either the current limit or over-temperature  
circuits in any combination are constantly active for  
more than approximately ten milliseconds, the  
FLG(A/B) pin is pulled to ground internally through  
an open drain device. The 10ms delay on the fault  
function is intended to prevent capacitive loads con-  
nected to one of the load switch outputs from acti-  
vating its respective flag when the device is turned  
on. The placement of a pull-up resistor between the  
FLGA or FLGB pin and the IN pin is recommended.  
Reasonable values for the pull-up resistor should  
range from 10kΩ to 100kΩ. Since the fault flags are  
open drain terminals, they may be pulled up to any  
voltage that is not greater than the level present on  
the IN pin. This is done to allow the AAT4626 to sig-  
nal ancillary circuitry that is powered by voltage lev-  
els less than the level on the IN pin.  
Output Capacitor  
In order to insure stability while the device current  
limit is active, a small capacitance of approximately  
1µF should be used on each output. When either  
output of the AAT4626 is activated using the  
EN(A/B) function, there are no momentary current  
transients, as in the case when a short circuit is sud-  
denly applied to a device that is already on. Refer to  
the Typical Characteristics curve "Turn-On/Off  
Response." Regardless of output capacitor size,  
output current on either output is limited to the value  
allowed by the threshold determined by the internal  
current limiting circuitry. Refer to the internal current  
limit threshold specifications stated in the Electrical  
Characteristics section of this datasheet. This per-  
mits very large output capacitors to be used.  
If a fault flag delay greater than 10ms is required,  
addition delay may be added by use of an RC filter.  
As shown in Figure 1, an RC filter can be added to  
the fault flag output.  
For example, USB ports are specified to have at  
least 120µF of downstream capacitance from their  
controlling power switch. An output capacitance as  
large as 1000µF would not disturb the input power  
supply to an AAT4626 used to control a USB port.  
Reverse Voltage  
The AAT4626 is designed to control current flowing  
from IN to OUT. If a voltage is applied to OUT which  
is greater than that on IN, a large resulting reverse  
current may flow, potentially damaging the AAT4626.  
EN Inputs  
The AAT4626 has two enable inputs, ENA and  
ENB. These two enable inputs allow the AAT4626  
to independently control each respective output.  
The device is available in both active high EN  
enable and active low (EN) enable versions. For  
specific part numbers, refer to the ordering informa-  
tion section. When both the A and B outputs of the  
AAT4626 are in the off state, the respective outputs  
are an open circuit and the device quiescent current  
consumption is reduced to less than 1µA. The ENA  
and ENB threshold voltages are set to allow the  
AAT4626 to be controlled by 5V TTL levels, as well  
Under-Voltage Lockout  
The AAT4626 has been designed with an under-volt-  
age lockout control circuit. The under-voltage lock-  
out prevents the output MOSFET devices from turn-  
ing on until VIN exceeds the typical UVLO threshold  
of 2.3V. During operation, the device will automati-  
cally shut down if VIN falls below the UVLO threshold  
and the fault flags will be toggled.  
4626.2006.05.1.2  
9